background image

12

If you are 

redecorating 

your home, paint fumes can contaminate the alarm

– 

temporarily 

cover the unit with a plastic bag (during this time the alarm

will not function). 

Never paint the alarm itself. 

Only remove the bag when the paint is thoroughly dry.

If you 

extend your property

, review your alarm requirements.

Smoke alarms 

should be replaced every 10 years 

or sooner.

These products are designed for 

domestically scaled premises.

21. Limitations of Smoke Alarms

Warning! 

Alarms are devices that can provide early warning of possible fires at a

reasonable cost; however, alarms have sensing limitations. 

Ionisation 

type alarms

offer a broad range of fire sensing capability but are better at detecting fast flaming
fires than slow smouldering fires. 

Optical (Photo-electric) 

alarms sense slow

smouldering fires better than flaming fires. Home fires develop in different ways and
are often unpredictable. Neither type of alarm (Photo-electric or Ionisation) is always
best, and a given alarm may not always provide warning of a fire.

Loose batteries, where fitted must be of the specified type, in good condition and
installed properly.

All alarms must be tested regularly to make sure the batteries and the alarm circuits
are in good operating condition.

Smoke alarms cannot provide an alarm if smoke does not reach the unit. Therefore,
smoke alarms may not sense fires starting in chimneys, walls, on roofs, on the other
side of a closed door or on a different floor. If the alarm is located outside the
bedroom or on a different floor, it may not wake up a sound sleeper. Equally heat
alarms will only be triggered if they are correctly sited to detect heat. The use of
alcohol or drugs may also impair ones ability to hear the alarm. For maximum
protection a smoke alarm should be installed in each sleeping area on every level of
a home. Hearing impaired occupiers should consider fitting additional strobe
accessories to give a visual alarm.

Although smoke alarms can help save lives by providing an early warning of a fire,
they are not a substitute for an insurance policy. Home owners and renters should
have adequate insurance to protect their property.

22. Service and Guarantee

If after reviewing this manual you feel that your smoke alarm is defective in any way,
do not tamper with the unit. Return it prepaid for servicing to: Kidde Safety Europe,
Mathisen Way, Colnbrook, SL3 0HB, UK – Email: [email protected], or refer to
your supplier or Landlord.

Guarantee

Kidde Fyrnetics warrants to the purchaser that the enclosed smoke alarm (but not
any loose batteries) will be free of defects in material, workmanship or design under
normal use and service for a period of 5 years, (5 years including battery on 
Sealed in/Long Life [LL] products from the date of purchase). The obligation of Kidde
Fyrnetics, under this guarantee is limited to repairing or replacing any part which we
find to be defective in material, workmanship or design, free of charge to the
customer, upon sending the alarm with proof of date of purchase, postage prepaid,
to Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK.

This guarantee shall not apply to the alarm if it has been damaged, modified,
abused or altered after the date of purchase, or if it fails to operate due to incorrect
selection, siting, installation or maintenance.

The liability of Kidde Fyrnetics, arising from the sale of this alarm or under the terms
of this guarantee shall not in any case exceed the cost of replacement of the alarm,
in no case, shall be liable for consequential loss or damaged resulting from the
failure of the alarm or for the breach of this or any other guarantee, express or
implied, or for damaged caused by failure to abide by the instructions supplied.

This guarantee does not affect your statutory rights.

Kidde Fyrnetics makes no guarantee, express or implied, written or oral, including
that of merchantability or fitness for any particular purpose, with respect to the
battery, except Sealed in/Long Life cells.

Summary of Contents for 19HI

Page 1: ...netics co uk Kidde Fyrnetics 2000 Lic No 7861 BS 5446 Pt 1 1990 19 series BS 5446 Pt 1 2000 29 series Read this manual thoroughly and follow its instructions regards regular maintenance it could save...

Page 2: ...alled and maintained as per KIDDE Fyrnetics instruction manuals 3 Types of Alarm a Power Supply DC alarms 9V battery powered units but will only function if battery is in good condition check regularl...

Page 3: ...alarm stand back so your hearing is not damaged by the 85dB sounder 5 Recommended Locations for Smoke Alarms Ideally locate near centre of room on ceiling but at least 300mm 12 from any light fixture...

Page 4: ...larm could be interrupted e g next above a door air vent heater air con unit Areas where routine maintenance or operating hush test button is difficult e g top of stairwells 7 Installing Alarm Remove...

Page 5: ...ealed in Alarms Open battery door on rear of alarm Remove freshness tab prior to powering up ensuring red spring loaded battery flag is under battery The alarm battery door will not shut without a bat...

Page 6: ...ration and L E D Status When your alarm is correctly functioning the red L E D will blink about once a minute If the alarm senses products of combustion it s 85dB horn will by activated The red L E D...

Page 7: ...u may not be able to reach your children It is important they know what to do What to do when the Alarm Sounds Leave immediately by your escape plan Every second counts so don t waste time getting dre...

Page 8: ...tion causing the alarm Note Dense smoke will override the hush control feature and sound a continuous alarm Caution Before using the alarm hush feature identify the source of the smoke and be certain...

Page 9: ...ss above 12 Timing of Installing Decorating Do not install if property remains damp unheated During building work dust and other contaminants e g paint fumes will enter the alarm causing possible nuis...

Page 10: ...aceable battery on Sealed in Long Life models These models will be indicated on the product s label on the underside additionally there is no battery drawer To check charge on these models push and ho...

Page 11: ...t button pressed and held 5 Interconnected alarms do not sound when test button is pressed and held Possible cause solutions Low or flat battery Replace battery on Sealed in Long Life models contact s...

Page 12: ...ional strobe accessories to give a visual alarm Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insurance policy Home owners and rent...