![background image](http://html1.mh-extra.com/html/kidde/10sco/10sco_user-manual_1965208010.webp)
o System announces “PUSH TEST BUTTON” when the unit is
powered up, reminding user to activate the Test Button.
• One “chirp” every 30 seconds is an indication that the alarm
is malfunctioning. If this occurs call the Consumer Hotline at
0800 917 0722.
• After ten (10) years of cumulative power up, this unit twice
every 30 seconds. This is an "operational end of life" feature
which will indicate that it is time to replace
the alarm.
• Loud 85 decibel alarm
• HUSH Control Feature that silences the unit during nuisance
alarm situations (see page 16).
• Oversized test button for easy activation
• Test button performs the following functions:
o Tests the units electronics and verifies proper unit operation
o Resets the unit during CO alarm
o Peak Level Memory
o Activates or cancels Hush® Feature
• Mounting bracket designed for easy orientation of the unit
• Green and red LED lights that indicate normal operation and
alarm status
o Green Light: The green LED will be lit continuously or flash
every 30 seconds to indicate the unit is operating properly.
In HUSH® mode the LED blinks every 2 seconds and once
per second if it is the initiating alarm.
o Red Light: When a dangerous level of smoke or carbon
monoxide is detected the red LED light will flash and the
corresponding alarm pattern (depending on the source)
will sound. If the unit malfunctions, the red LED light will
flash and the unit will chirp every 30 seconds indicating a
system problem.If the red LED flashes every 60 seconds
WITHOUT an audible chirp, this is the pre-warning that
the battery will soon need replacing.
• The alarm is battery operated with a 9V battery.
• Tamper Resist Feature that deters children and others from
removing the battery or alarm
5
Features