13
English
KEY Algorithm:
You are now ready to start running
the KEY algorithm. Press and hold the KEY button for
5 seconds until the Gain Match LED slowly flashes,
then release the button. Start the “Key500.1 Sweep”
track. While the KEY algorithm is running the Gain
match LED will flash slowly. This process will take
about 1.5 minutes and is very loud. After the sweep
track finishes, pause the audio. The Gain match LED
will go dark while it is calculating the corrections.
This takes about 30 seconds. If the algorithm runs
through successfully the Gain Match LED will begin to
flash rapidly for 1.5 seconds. If the algorithm fails, the
Gain Match LED will go solid. In the event of a failure
you will need to short press the KEY button to exit
the KEY Setup. See the manual for trouble shooting
guide if the algorithm fails.
After the algorithm has been run successfully you
can do a single button press of the Key button to
A/B the Key audio output in original and corrected
form. A single flash indicates corrections are ON,
and a double flash indicates corrections are OFF. To
reset the KEY algorithm, press and hold programming
button 10 seconds. The Gain Match LED will flash 5
times indicating the KEY Algorithm has been reset.