3
PRODUCT OVERVIEW
BAT+ Positive Post
M8 x16 SS Bolt & Washer
KASMARTBG Module
Button/Indicator LED
Remote Override Switch 2.8M
Note:
KASMARTGB
will be delivered with all hardware depicted above.
BAT+ Positive Clamp
LOAD+ Terminal
M8 Thread Insert
Switch plug
Negative
Terminal
Wire
Page 1: ... SMART BATTERY GUARD KASMARTBG V0 8 USER MANUAL ...
Page 2: ...rger The KickAss Smart Battery Guard KASMARTBG comes pre configured with automatic cut in and cut out voltages to protect the vehicle starter battery from accidental over discharge When configured as a VSR the KASMARTBG will isolate the starter battery from the auxiliary battery to disable any charge transfer between the batteries after the engine has been switched off Automatic LVD Function overview...
Page 3: ...ION BLUETOOTH UNIT WEIGHT UNIT DIMENSIONS PACKAGE WEIGHT PACKAGED DIMENSIONS 8 18V 12V BATTERY SYSTEM ONLY 1MA 100A 250 300A FOR LESS THAN 10 SEC 20 C TO120 C M8 PLUS POSITIVE TERMINAL POST CLAMP BLE4 2 0 34KG 81 X 76 X 21MM 0 4 KG 200 X 140 X 40MM SMART BATTERY GUARD CONFIGURATIONS LVD CONFIGURATION VSR CONFIGURATION ...
Page 4: ...M8 x16 SS Bolt Washer KASMARTBG Module Button Indicator LED Remote Override Switch 2 8M Note KASMARTGB will be delivered with all hardware depicted above BAT Positive Clamp LOAD Terminal M8 Thread Insert Switch plug Negative Terminal Wire ...
Page 5: ...y default as a VSR Default VSR Settings Cut in voltage 13 2V Cut out voltage 12 25V Recommend VSR Settings AGM GEL WET CAL Cut in voltage 13 2V Cut out voltage 12 6V Typical Starter Battery Connections Chassis Ground Vehicle Positive Battery Positive Post Remote Override Switch Load Positive AUX Battery Chassis Ground Starter Battery AUX Positive Chassis Ground Vehicle Positive Starter Battery Veh...
Page 6: ...positive clamp to KASMARTBG positive post 3 Fit KASMARTBG clamp to battery post 4 Tighten both clamps carefully 5 Connect remote override switch if needed and run to cab dash 6 Remove M8 bolt from LOAD terminal and fit all load positive cables 7 Secure KASMARTBG Negative Terminal wire to battery negative ...
Page 7: ... the Bluetooth Application and configure Cut in and Cut out Voltage Recommend Settings AGM GEL WET CAL Cut out voltage 10 5V Cut in voltage 11 5V Typical Aux battery connections with NO LVD KASMARTBG Installed with Aux battery loads Aux Battery Charger Positives Load Positives Load Negatives Aux Battery Charger Positives Load Positives Load Negatives KASMARTBG Module Remote Override Swith Negative ...
Page 8: ...erminal fit KASMARTBG BAT to auxillary battery positive terminal add charging positive connections here also then screw down bolt 2 Remove M8 bolt from KASMARTBG LOAD terminal fit auxillary load connections and screw down bolt 3 Secure KASMARTBG Negative Terminal wire to battery negative ...
Page 9: ...Ÿ The Bluetooth application will begin to search for any available KASMARTBG devices when the application is started Ÿ Once the Bluetooth application can see the KASMARTBG the device and received signal strength will be displayed Ÿ Click on the device icon to connect IOS Android Registering the KASMARTBG on the mobile device Ÿ To register the KASMARTBG with the mobile device select OK when prompte...
Page 10: ...figurable parameter at which the KASMARTBG will disengage the relay once the starter battery voltage drops the below set voltage Ÿ Cut out timeout Configurable parameter of time which the KASMARTBG will wait before disengaging the relay once the starter battery voltage drops below the cut out voltage Ÿ Cut in voltage Configurable parameter at which the KASMARTBG will engage the relay once the starter...
Page 11: ...The LED will pulse GREEN momentarily to indicate the Cut out voltage parameter has changed The number of BLUE LED pulses should now have increased The pre configured cut out voltage operates as a circular menu i e if the current pre configured cut out voltage is set to 12 50V 5 LED pulses pressing the LED button will return the setting to 11 50V 2 LED pulse To return to automatic operation mode hold...
Page 12: ...auxiliary loads if the vehicle is in storage for an extended period of time or to connect the auxiliary battery to the starter battery to jump start the vehicle Manual mode can be entered into from the Bluetooth application and the local LED button on the KASMARTBG device Using manual mode through the Bluetooth application Manual mode IOS Android Enable disable manual mode switch the Auto Mode sel...
Page 13: ...by 4 quick pulses followed by 1 flash every second The device is now in manual mode and can be operated via the Bluetooth application or the LED button on the KASMARTBG To engaged disengaged the KASMARTBG relay press the LED button on the device The LED will pulse GREEN once when pushed HOLD FOR 6 SECS 3 SECS 4 QUICK GREEN PULSES 1 2 SEC RELEASE 1 2 SEC HOLD FOR 6 SECS 3 SECS 4 QUICK GREEN PULSES 1...
Page 14: ...y 4 seconds Battery voltage is below the cut out voltage KASMARTBG relay is disengaged and starter battery and load terminals are disconnected 4 SECS PULSE 4 SECS PULSE 4 SECS PULSE PRESS One press will reset the device disconnecting the starter battery and Load terminal momentarily before reconnecting Press 3 time to immediately disengage the relay while in this state Using Override Switch when b...
Page 15: ...to expose sticky pad Prep surface by wiping clean to remove dust and grease Then press firmly to desired mounting position 2 8m cable can be run from KASMARTBG to remotely mount switch where convenient eg From under bonnet to vehicle cab through fire wall grommets ...
Page 16: ......