13
There are error codes that may be displayed. These will be displayed in the
following way:
FAULT CODES
If all battery type selection lights are flashing simultaneously please see troubleshooting guide below.
MODE
BATTERY TYPE
WET
GEL
AGM
CALCIUM
LITHIUM
Stage LED
Solar input
high voltage
Solar input
reverse
Alternator
high voltage
Alternator
input reverse
Output
fault mode
S1
LED
Cause
Remedy
Over voltage is detected
at solar input
Solar input is reverse
connected
Overvoltage is detected
at alternator
Alternator input is
reverse connected
Output battery is
reverse connected
Overvoltage is detected
at output
Output open circuit
or dead battery
Check solar panel
open circuit voltage
Check solar input
connection
Check vehicle
battery voltage
Check alternator
input connection
Check output
cable connection
Check auxiliary
battery voltage
Check auxiliary battery
voltage & cable connections
S2
LED
S3
LED
S4
LED
KickAss constantly updates
frequently asked questions,
troubleshooting, videos and
specifications, please visit:
www.kickass.com.au
for the most up to date
information.
NOTE:
To activate the Charger when the auxiliary battery is below 9V, connect a set of jumper cables from a fully
charged battery (such as your start battery) to your auxiliary battery and check that the charging LED on the DC-
DC charger flashes after minimum cut in voltage is reached and 120 second delay has passed. You can then
remove the jumper cables.