CHARGING STAGE PROFILE
BULK
ABSORPTION
FLOAT
GEL
100%
Current
Until
14.1 V
AGM
100%
Current
Until
14.7 V
WET
100%
Current
Until
14.4 V
CALCIUM
100%
Current
Until
15.3 V
LifePO4
100%
Current
Until
14.5 V
Constant
14.1 V
Until 2.6A
Constant
14.7 V
Until 2.6A
Constant
14.4 V
Until 2.6A
Constant
15.3 V
Until 2.6A
Constant
14.5 V
Until 2.6A
STAGE
DESCRIPTION
CHOOSING THE BATTERY TYPE
The battery type setting must be confirmed during device installation. When the auxiliary
battery is connected, press and hold the Mode button for 2-4 seconds then releaase to
change the battery type setting. The selected battery type will be saved as the new
default.
The default priority setting is ALTERNATOR. To change the Solar priority, press and hold
the Solar Priority button for 2-4 seconds, then release, to set the the solar priority. The
priority setting will be saved as the new default.
9
NOTE:
When in FLOAT stage, the battery is fully charged. At float stage, when the battery voltage drops to
0.3V below the specified float voltage for the battery type connected, the charger will restart charging
form the BULK stage.
13.5V
at 100%
Current
Max
13.4V
at 100%
Current
Max
13.4V
at 100%
Current
Max
13.6V
at 100%
Current
Max
13.6V
at 100%
Current
Max