Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

WorkUp

®

 Adjustable Table - Model HF

Assembly Instructions

Electrical Cables (cont.)

4.  Carefully invert the table to its 

upright position. 

Caution:

 The table 

is very heavy. Two or more people 

are required to turn table upright. 

5.  Adjust leveling glides to 

accommodate for uneven floor. 

6. Tuck the loose cables into the open 

side of the plastic wire trough  

(Figure 8, Detail G). 

7. Insert the power cord into the socket 

on the control box (Figure 7). 

Note:

 Do not attempt to adjust the 

table until the system is initialized. 

Initializing The Table

                                          

1.  Plug the power cord into a 110V AC 

outlet (Detail F). 

2.  Simultaneously press and hold both 

the up and down arrows, holding 

for five seconds to zero the system. 

Continue to hold both buttons until 

both legs are at the midpoint of the 

travel. 

3.  Adjust the table to its highest and 

lowest positions while checking that 

the cables and power cord do not 

bind or pull loose.

Operating the Table

Note:

 When adjusting the table 

always be sure hands are clear of any 

potential pinch areas created by the 

table and adjacent furniture. 

1.  The table can be adjusted to the 

desired height by pressing the up or 

down arrows on the keypad.

Figure 7

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should always be 

followed, including the following: 
Read all instructions before using (this furnishing).

DANGER:

 To reduce the risk of electric shock:

1. Always unplug this furnishing from the outlet before cleaning.

WARNING:

 To reduce the risk of burns, fire, electric shock, or injury to 

persons:
1. Unplug from outlet before putting on or taking parts off parts.
2. Close supervision is necessary when this furnishing is used by, or near 

children, invalids, or disabled persons.

3. Use this furnishing only for its intended use as described in these 

instructions. Do not use attachments not recommended by the manufacturer.

4. Do not use outdoors.
5. 

WARNING:

 Risk of Electric Shock-Connect this furnishing to a properly 

grounded outlet only. See Grounding Instructions.

SAVE THESE INSTRUCTIONS

CAUTION:

 If Channels (Wire Troughs) are used they are not to be used for 

routing extension cords. Power supply cords are not to be routed across or 
through more than one complete unit/worksurface.

Detail G

plastic wire trough

cables

Detail F

grounding

pin

grounded

outlet

6

Summary of Contents for WorkUp HF

Page 1: ...are tight Figure 1 Detail A Feet to Columns Assembly 1 Set the column on end with the smaller inner square tube on the floor The threaded holes visible on the end of the column will be in a rectangular not square pattern Figure 1 2 Place the foot over the column end so the column fits into the square hole in the foot The slotted holes in the foot should line up with the four holes in the column en...

Page 2: ...nug then tighten each screw one quarter turn at a time in a diagonal pattern until all four screws are tight Figure 2 Detail A 4 Attach the second foot column in the same manner Figure 2 Base to Tabletop Assembly Note Except for the P shaped cable clamps the tabletop is pre drilled for installation of all components 1 To avoid scratching the tabletop place it with the top side down on a soft prote...

Page 3: ... using two screws for standard keypad or four screws for memory display keypad 10 x 11 16 tapping screws Figure 4 Note The hole pattern for the keypad will accommodate the standard keypad and the memory display keypad so all holes will not be used 2 Position and mount the control box to the underside of the tabletops at one of two pre drilled hole locations Attach the control box at the left or ri...

Page 4: ...ts of any depth table as illustrated in Detail C If the wire trough is not center mounted over the tabletop supports the tabletop depth determines the mounting location If the wire trough is to be mounted under tabletops of 22 or 24 in depth see Figure 5 If the wire trough is to be mounted under tops of 30 or 36 in depth see Detail B 2 Align the wire trough mounting holes to the appropriate holes ...

Page 5: ...re pushing it into the socket Detail D 2 Connect the keypad cable to the HS socket on the control box Figure 6 3 Using the P shaped cable clamps and 10 x 3 4 self drilling screws provided secure the column and keypad cables to the worksurface Be sure to position a cable clamp within 8 of where the cable connectors plug into the control box Detail E Note No cable clamps are required for the power c...

Page 6: ...ating the Table Note When adjusting the table always be sure hands are clear of any potential pinch areas created by the table and adjacent furniture 1 The table can be adjusted to the desired height by pressing the up or down arrows on the keypad Figure 7 IMPORTANT SAFETY INSTRUCTIONS When using an electrical furnishing basic precautions should always be followed including the following Read all ...

Page 7: ...7 WorkUp Adjustable Table Model HF Assembly Instructions ...

Page 8: ...Bellevue Street P O Box 8100 Green Bay WI 54308 8100 Tel 1 800 424 2432 www ki com 2019 KI All Rights Reserved Litho in USA Code KI 62450R6 KI PDF 0419 WorkUp Adjustable Table Model HF Assembly Instructions ...

Reviews: