background image

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

Assembly Instructions

Vertical Cable Manager

November 2018

Required Tools

•  Cordless Power Drill

•  Screwdriver

Vertical Cable Manager Installation

Note: 

If the Vertical Cable Manager 

will mount to the underside of 

the tabletop, proceed to “Tabletop 

Mounted Cable Manager” 

instructions below. If the Cable 

Manager will mount to the underside 

of the wire trough, proceed to “Wire 

Trough Mounted Cable Manager” 

instructions below. 

Tabletop Mounted Cable Manager

1. Position the top mounting plate 

underneath the back, non-user side 

of the tabletop at the desired location. 

Assure that the power cord can be 

routed easily to the mounting plate 

and to a power source (Figure 1). 

2. Using the top mounting plate as a 

template underneath the table, align 

the unit straight, and 

1

/

4

” back from 

the table edge, then mark the two 

mounting hole locations and move 

the plate away (Figure 1). 

3. Carefully bore a 

3

/

32

” pilot hole at 

the center of each marked location, 

underneath the tabletop using a cordless 

power drill. Take care to not drill too 

deep, piercing the table top (Figure 1). 

4. Align the mounting holes of the top 

mounting plate with the pre-drilled 

holes underneath the tabletop. Secure 

the mounting plate to the table using 

two #9 x 1” flat head screws. Take care 

to not over tighten (Figure 2). 

5. Proceed to page 2 for “Vertical Cable 

Manager Installation” instructions. 

marked for

drilling

cordless

power drill

tabletop

leg column

(adjusted to

maximum

height)

Figure 1

power

cord

top

mounting

plate

Figure 2

top

mounting

plate

#9 x 1”

flat head

screws

drilled

mounting

holes

tabletop

wire

trough

tabletop

leg column

(adjusted to

maximum

height)

Figure 3

top

mounting

plate

Detail A - Top Mounting Plate in Wire Trough

top

mounting

plate

wire

trough

smaller

access hole

(to hold top

mounting plate)

larger access hole

(to feed cables

through wire trough)

Wire Trough Mounted Cable 

Manager

Note: 

Two differently sized access 

holes are provided on the wire trough. 

The smaller hole is used to hold the 

top mounting plate to the trough 

while the larger hole is available to 

feed cables through the trough. 

1. Position the top mounting plate 

underneath the wire trough at the 

smaller access hole location. Assure 

that the power cord can be routed 

easily to the mounting plate and to a 

power source (Figure 3). 

2.  Insert one end of the top mounting plate 

up through the smaller wire trough 

access hole, push it fully into the trough, 

then allow the connector end to protrude 

down through the access hole as 

illustrated (Figure 3 & Detail A).

Reviews: