background image

EN

7

Operation Instructions

           (3) Sleep Mode: In natural sleep mode, the wind speed LED changes with the 30-minute cycle 

                  change, and does not change with the change of natural wind. The running rule of sleep 

                  wind is as follows.

                 - High: 30 minutes high level natural wind - 30 minutes medium level natural wind - low  

                    level natural wind (holding)

                 - Medium: 30 minutes medium level natural wind - low level natural wind (holding)

                 - Low: Low level natural wind

c) Other System Function

    1.  Environmental protection feature: 

          If there is no operation in 60 seconds, all LEDs turn on semi-bright. When there is any operation, 

          the LEDs enter fully bright state immediately.

    2.  Water level protection function:

         When the cool function is turned on, the water pump works for 50 seconds, and if the    

         program detects lack of water level, the pump stops working, the buzzer alarms 10 seconds.

    3. Separation power off function: 

         When the water pump is taken out from the tank, it turns off immediately. Humidify function is 

         invalid, while other functions are normal.

    4. Air dry function: 

         If Honeycomb Filter on the rear filter net of the unit needs to be dried after using the 

         cool / humidify function and before packing the unit. Press and hold “Speed” button on the 

         panel for 3 seconds to turn on the air dry function. When the air dry function is turned on, 

         the wind speed jumps from the current speed level to high level and runs for 20 minutes. At this   

         time, other functions are turned off, the high level indicator turns on, flashes in 0.5 seconds 

         interval, and turns off after 20 minutes. When the air dry function is turned on, all function 

         buttons except “On / Off” button are invalid. If “On / Off” button is pressed down before 20 

         minutes are over, the remaining time of air dry function won’t be saved. When the air dry 

         function is turned on again, it will still run 20 minutes before shutdown.

    5. Power failure memory function:

        i.    In power on state, the unit beeps ten times when the power is restored after power failure, 

              and there is no display or action; the unit waits 30 seconds and resumes the last state.  

        ii.   If you press the ON button within 30 seconds when the power is restored, the last state is 

              restored immediately. 

         Note: The function is invalid when it is under sleeping or natural wind mode.

     6. Prevent long time accidental work: 

         This function can prevent the unit from long time work if the user forgets to turn off the unit.  

         This function requirement is as follows: The unit turns off automatically after continuous work of  

         

15 hours if the timer is turned off

Summary of Contents for EAC20

Page 1: ...ortant Mustahak Please read this manual carefully before operating this product Keep this manual handy for further reference Sila baca buku panduan ini dengan teliti sebelum menggunakan produk ini Sim...

Page 2: ...ckle Left Shell Remote Control Receiver Water Level Display Window Reel Picture is for illustration purpose only Top Panel Cover Rear Casters Right Shell Water Pump Rod Stopper Horizontal Louver Remot...

Page 3: ...rty dusty or polluted environments 4 Insert the plug to the AC mains securely Do not remove power plug by pulling through its cord Do not operate with wet hands or when the plug is wet 5 Do not fill w...

Page 4: ...flux 16 Do not install this appliance in locations containing inflammable or explosive gases and sprays Do not expose it directly to sunlight for a long period of time 17 Do not insert fingers wooden...

Page 5: ...button and the unit will turn off and enter standby mode Press this button again and the unit will resume last wind speed If the wind speed before shutdown is low or silent it starts from the medium...

Page 6: ...s T 90s T 90s stop stop Natural mode in medium speed Natural mode in low speed 2 Wind speed button The wind speed can be converted in the following sequence Silent low medium high silent and circulate...

Page 7: ...ore packing the unit Press and hold Speed button on the panel for 3 seconds to turn on the air dry function When the air dry function is turned on the wind speed jumps from the current speed level to...

Page 8: ...ider to the tank bottom Slide Water Pump Slider again to raise the pump rod to the top Loosen Water Tank Buckle on both sides A Water filling 1 You need to add water to the tank if the cool humidify f...

Page 9: ...dry function to dry the unit and the honeycomb filter then pull out the plug Loosen the Water Tank Buckle slide the Water Pump Slider to move the pump rod to the top and insert the Water Pump Rod Sto...

Page 10: ...CN 10 1 7 13 14 16 15 5 6 3 9 2 8 4 10 17 11 18 12 19 20 21 A B 1 13 14 15 16 2 3 4 5 6 7 8 9 10 17 18 19 20 11 12 21...

Page 11: ...CN 11 C x x x x 1 2 18 C to 45 C 45 C 3 4 5 6 MIN 7 8 9 10 11 Khind Mistral M Sdn Bhd EAC20 220 240V 50Hz 110W 20 480 1260rpm 9 17m min 323CFM 2000 8 390 x 342 x 897 3...

Page 12: ...CN 12 12 13 14 15 16 17 18 19 i ii iii 1 a b c 2 3 4...

Page 13: ...CN 13 A 1 2 B 1 1 2 2 3 3 1 2...

Page 14: ...CN 14 4 4 5 5 1 2 4 8 1 2 6 6 1 2 6 6 6 12 12 12 18 21 33 45 48 54 69 72 78 84 24 30 33 39 43 51 57 63 69 72 78 84 18 21 27 39 45 51 57 63 69 72 84 T 90 T 90 T 90 3 30 30 30 30...

Page 15: ...CN 15 C 1 60 2 50 5 10 3 4 3 20 0 5 20 20 20 5 i 30 ii 30 ON 6 15 A A 1 1 2 1 2...

Page 16: ...CN 16 5 2 3 4 3 5 i MAX ii iii 3 4...

Page 17: ...CN 17 7 8 6 B B 6 7 C C 1 1 3V CR2032 2 CR2032 8...

Page 18: ...angka Kiri Penerima Pancaran Alat Kawalan Jauh Tingkap Paparan Paras Air Gelendung Pelindung Panel Atas Roda Belakang Kerangka Kanan Penghalang Rod Pam Air Daun Tetingkap Melintang Alat Kawalan Jauh G...

Page 19: ...Suhu bilik 18 C hingga 45 C Suhu air pengisian semula 45 C 3 Jangan operasikan perkakas ini di dalam keadaan persekitaran kotor atau tercemar 4 Masukkan plag AC dengan sebaiknya Jangan keluarkan plag...

Page 20: ...a perkakas 15 Jangan sandarkan perkakas ini pada dinding atau langsir atau objek lain yang mungkin menghalang aliran udara 16 Jangan memasang perkakas ini di lokasi yang mengandungi gas gas mudah terb...

Page 21: ...tidak menggunakan perkakas ini 4 Sekiranya perkakas tidak digunakan untuk tempoh yang lama tanggalkan tangki air buangkan air di dalamnya dan kemudian pasang semula dengan kemas Hidupkan fungsi udara...

Page 22: ...kalkan 2 Butang kelajuan Angin kelajuan angin boleh diubah mengikut aturan kitaran seperti berikut Senyap rendah Pertengahan Tinggi Senyap secara berkitaran LED akan menyala untuk menunjuk kedudukan m...

Page 23: ...ngsi Perlindungan Paras Air Apabila fungsi sejuk diaktifkan pam air akan berkerja selama 50 saat Jika dalam tempoh ini kekurangan air dikesan pam akan berhenti beroperasi dan penggera akan berbunyi se...

Page 24: ...a akan berbunyi beep 10 kali selepas bekalan kuasa kembali pulih Selepas 30 saat unit akan kembali beroperasi mengikut tetapan sebelumnya ii Jika anda menekan butan ON semula dalam tempoh saat tersebu...

Page 25: ...ras air terletak di sebelah hadapan perkakas Gambarajah 5 1 Jangan masukkan air melebihi paras maksimum 2 Pastikan air yang digunakan adalah bersih 3 Tip Jika terdapat sedikit bauan pada perkakas atau...

Page 26: ...Penerima Pancaran yang terletak pada unit Jika voltan bateri berkurangan sila buka penutupnya seperti ditunjukkan pada gambarajah 8 dan gantikan dengan bateri CR2032 yang baru Pastikan polar positif d...

Page 27: ......

Page 28: ...www khind com my...

Reviews: