52
4
1
CURRENT SENSE FAULT
current sense out of range
1.Short in motor or in motor wiring.
2. Controller failure.
★
4
2
HARDWARE FAILSAFE
motor voltage out of range
1.Motor voltage does not correspond to
throttle request.
2.Short in motor or in motor wiring.
3. Controller failure.
★
4
3
EE CHECKSUM FAULT
EEPROM fault
1. EEPROM failure or fault.
4
5
BATTERY DISCONNECT
FAULT
battery dsconnected
1. Battery not connected.
2.Poor connection to battery terminals.