MCC / MCC commands:
MCC-LOCATION
Enter text description of the door - opener
(max. 60 characters)
Parameters:
Module: 1..2
Door opener 1..2
e.g.: door opener #2 of module #2 should
be named „house west“:
“MCC_LOCATION 1 2 house west”
MCC-DESCRIPTION
Enter description of the door - opener
(60 char.)
Parameters:
Module: 1..2
Door opener 1..2
e.g.: door opener #2 on the module #1
should be named „clima“:
“MCC_LOCATION 1 2 clima”
MCC-STATE x x
Displays the status of the door opener:
Parameters:
Module: 1..2
Door opener: 1..2
Status: locked / unlocked / off
e.g.: door #1 on module #2 should open:
„MCC-STATE 1 2 unlocked“
MCC-TIMEOUT x x x
Determines the period after which the door
is unlocked after the unlock command was
sent.
Parameters:
Module: 1..2
Door opener: 1..2
Syntax: dhms
(days, hours, minutes, seconds)
e.g.: Door #1 on module #2 opens after 5
minutes and 30 seconds:
„MCC-TIMEOUT 2 1 5m30s“