Humidifier Assembly                          

 

 

Lower the tank into place until it is properly seated,       

using the enclosure and the base to align the   
tank. 

 

Air outlet is installed on the water tank

 

 
 
 
 
 
 
 

Filling the Water Tank                                                 

 

 

Always unplug unit before filling and replacing tank. 

 

Remove tank from the base. 

 

Turn upside down and remove the filler cap on the bottom of the tank by 

turning it counterclockwise.

 

 

Fill the tank with COOL tap water.   

 

DO NOT USE HOT WATER. Be sure to keep the tank   

free of debris.

 

 

NOTE: 

Using distilled or deionized   

water will prolong the life of the filter.

 

 

Replace the filler cap and turn clockwise until the LOCK. 

NOTE: 

Always make sure the filler cap is locked in place   

before inverting water tank. 

 

Setting the Controls                                                   

 

Turn Unit On. 

 

Plug power cord into a   

120V AC wall outlet only. 

 

Turn knob in a clockwise   

direction

to begin   

operation of unit.   

Turn knob to 

 

illuminate water tank for   
nighttime operation. 

Turn Unit Off. 

 

Turn unit off when desired room humidity is achieved. 

 

Always turn unit off when water tank becomes empty. 

 

Unit will automatically stop creating mist when water   

level in base is very low and red light shows. 
Do not let water sit in tank for more than 24 hours. 
This can encourage bacterial growth. 

 

Disconnect when not in use. 

 

Direction of the mist.

 

The air outlet can rotate 360 degrees,   
adjusted in accordance with the preferences toward.

 

 

How to Clean

 

IMPORTANT:

 Clean your humidifier regularly (every 2 weeks or more as 

needed) to help eliminate odors.   

CAUTION:

 

Disconnect the power cord before cleaning the unit. 

1.  Turn OFF and unplug the humidifier. 
2.  Remove the water tank from the base. 
3.  Pour all water from the tank. DO NOT USE SOAP OR DETERGENTS AND 

NEVER USE ABRASIVE CLEANERS. 

4.  Rinse the Water Tank thoroughly with clean water or with a mild bleach and 

water solution. 

5.  Take brush stored in base and clean off mineral deposits and debris from 

nebulizer and water sensor. 

6.  Wipe all surfaces of the base unit with a soft DRY or slightly dampened 

cloth.  
DO NOT IMMERSE THE BASE UNIT IN WATER, AN ELECTRIC SHOCK 
MAY RESULT OR THE HUMIDIFIER MAY BE DAMAGED. 

7.  Prior to storage, make sure all components are completely dry. 

 

Technical Specifications 

Voltage 

120V~60Hz 

Power Consumption

36W 

Product Holder 

Join-One Electric (Shenzhen) Co.,Ltd. 

Subject to technical modification 

 

 

P6-14606 