background image

IMPORTANT SAFETY INSTRUCTIONS

Be sure the electrical service is adequate for the model you have
chosen. This information can be found on the serial plate, which
is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The power
cord is equipped with a three-prong grounding plug for protection
against shock hazards.
Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or circuit breaker,
have a qualified electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place.
This could result in mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

WARNING

For your safety

Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or
an adaptor plug. Do not remove any prong from the power cord.

WARNING

Electrical Infor mation

NOTE

The power supply cord with

this air conditioner contains a current
detection device designed to reduce
the risk of fire.
Please refer to the section Operation
of Current Device for details.
In the event that the power supply
cord is damaged, it can not be
repaired.It must be replaced with a
cord from the Product Manufacturer.

,

,

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding plug
and current detection device

Operation of Cur rent Device

The power supply cord contains a current device that senses damage to the power cord. To test your power
supply cord as follows:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a

click as the RESET button pops out.

3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by

a light on the plug head.)

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

The power supply must be replaced if it fails reset when either the TEST button is pushed, or it can not be
reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it can not be repaired. It MUST be replaced by one

NOTE:

obtained from the

product manufacturer.

4

Summary of Contents for KSTAW05A

Page 1: ...Model KSTAW05A KSTAW06A WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference...

Page 2: ......

Page 3: ...Producto...

Page 4: ...1 866 646 4332 1 866 646 4332...

Page 5: ...r for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play...

Page 6: ...ire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and...

Page 7: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not sing the un...

Page 8: ...NOTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the...

Page 9: ...miliarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the unit control alone or th...

Page 10: ...DO THIS Press to lower Press or hold either Left or Right button until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 62 F 17 C and 8...

Page 11: ...n the display will show the actual room temperature not the set temperature as in the cooling mode TO USE THE ENERGY SAVER FEATURE Press the button Auto Cool Dry Fan Low Auto Med High Fan Mode Follow...

Page 12: ...he control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous temperature setting Turning...

Page 13: ...tes interval This feature can be activated from the remote control ONLY The remote control serves as a remote thermostat allowing for the precise temperature control at its location ADDITIONAL THINGS...

Page 14: ...n use TOOLS NEEDED CAUTION Phillips Screw Driver Drill If pilot holes are needed When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils Top Rail H...

Page 15: ...nel be sure to use the proper panel for each side When installed the flange for securing the panel in place to the window sill will be facing into the room necessary for proper condensed water utiliza...

Page 16: ...g 7 Drive 3 4 19mm locking screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 4 Fig 7 Fig 8 12 Fig 4 C Onc...

Page 17: ...t Accumulated Rain Water or Condensation must be allowed to drain out Storm window frame or other obstruction 11 2 MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill...

Page 18: ...14...

Page 19: ...F Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the...

Page 20: ...is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the...

Page 21: ...1 866 646 4332...

Page 22: ...Modelo Manual del Usuario Unidad de aire acondicionado de ventana Antes de usar su aire acondicionado lea con cuidado este manual y gu rdelo para su consulta posterior KSTAW05A KSTAW06A...

Page 23: ...as a los problemas comunes en la pare de soluciones a problemas Si usted revisa la parte de Soluciones a Problema primero a lo mejor no necesitar llamar para servicio PRECAUCI N Contactar con el t cni...

Page 24: ...os aparatos en el mismo enchufe No lo maneje con las manos h medas o en un ambiente h medo No dirija el flujo de aire directamente a los ocupantes de la habitaci n Esto puede producir una descarga el...

Page 25: ...o lo desconecte Corte la corriente principal cuando no use la unidad por un periodo prolongado Si se usa con las ventanas abiertas se pueden mojar los muebles y el interior de la habitaci n Se puede p...

Page 26: ...te sea posible el acceso al recept culo No encienda el aparato de aire acondicionado si no ha colocado en su sitio la cubierta protectora Esto podr a producir da os mec nicos en el aparato de aire aco...

Page 27: ...continuaci n y todas sus funciones En las p ginas 6 a 8 puede encontrar una descripci n detallada de cada bot n y sus funciones La unidad se puede controlar con el panel de control o con el control r...

Page 28: ...ra ver en pantalla la temperatura real del ambiente consulte la secci n Para operar solo en modo ventilador en la p gina 7 PARA AJUSTAR LAS VELOCIDADES DEL VENTILADOR NOTA Presione el bot n Fan Ventil...

Page 29: ...uede seleccionar cualquier velocidad del ventilador en modo FAN VENTILADOR La pantalla mostrar la temperatura ambiente real No se puede ajustar la temperatura MODO DE FUNCI N DE DESHUMIDIFICADOR En mo...

Page 30: ...horas TEMPORIZADOR APAGADO Cuando se fija y visualiza la hora de inicio autom tico presione otra vez el bot n TIMER TEMPORIZADOR La luz de TIMER OFF TEMPORIZADOR APAGADO se iluminar para indicar que h...

Page 31: ...MIR se puede cancelar en cualquier momento durante el funcionamiento con s lo presionar el bot n SLEEP DORMIR PARA USAR LA FUNCI N DE VERIFICACI N DEL FILTRO NOTA La funci n CHECK FILTER VERIFICAR FIL...

Page 32: ...Para convertirlos mantenga presionados los botones de Temp Timer temperatura y temporizador izquierdo y derecho al mismo tiempo por 3 segundos Rejillas de ventilaci n direccionales Las rejillas de ve...

Page 33: ...o 1 2...

Page 34: ...acia el interior de la habitaci n A Sostenga el panel de acorde n en una mano y jale con cuidado el centro para liberar el extremo abierto Vea la Fig 2 Cuando se haya instalado el panel al lado del ga...

Page 35: ...riel superior de la unidad 3 Extienda los paneles laterales hacia el marco de la ventana Fig 6 4 Coloque el fijador entre las extensiones del marco y el alf izar de la ventana tal como se muestra Fig...

Page 36: ...ana aseg rese de que los orificios o ranuras de drenado no est n calafateados ni obstruidos con pintura Debe facilitarse el drenado del agua de lluvia o de condensaci n acumulada Desmontaje del AA de...

Page 37: ...sin el filtro de aire Limpieza del gabinete Aseg rese de desconectar el aire acondicionado para evitar el peligro de incendio o descarga el ctrica El gabinete y el frente de la unidad se pueden desemp...

Page 38: ...funcionar durante la noche Para descongelar el evaporador coloque el seleccionador en la posici n FAN Luego coloque el termostato en una posici n m s caliente El aparato enfr a pero la habitaci n est...

Page 39: ...ustifican nicamente por el per odo restante de la garant a original Responsabilidades de los consumidores NORMALES Esta garant a se aplica s lo a los productos de uso dom stico ordinario y el consumid...

Page 40: ...1 866 646 4332 18...