background image

C A U T I O N

C A U T I O N

Degradation of some product specifications can occur in the 
presence of ambient electromagnetic (EM) fields and noise 
that affects the product’s power line or I/O cables. The 
product self-recovers and operates to all specifications 
when:

• the source of the ambient EM field and noise is removed, 

• the product is protected from the ambient EM field, or 

• the product cabling is shielded from the ambient EM noise.

Safety Notices

Safety Information

The Keysight U1701B is safety-certified in 
compliance with the following safety and 
EMC requirements:
• IEC 61010-1:2001/EN 61010-1:2001 (2nd 

Edition)

• CISPR 11:2003+A1:2004
• IEC 61000-4-2:1995+A1:1998 +A2:2000 
• IEC 61000-4-3:2006
• IEC 61000-4-4:2004
• IEC 61000-4-5:2005
• IEC 61000-4-6:2003+A1:2004+A2:2006 
• IEC 61000-4-11:2004
• Canada: ICES-001:2004
• Australia/New Zealand: AS/NZS 

CISPR11:2004

Safety Symbols

C A U T I O N

C A U T I O N

CAUTION

 notice denotes 

a hazard. It calls attention 
to an operating procedure, 
practice, or the like that, if 
not correctly performed or 
adhered to, could result in 
damage to the product or 
loss of important data. Do 
not proceed beyond a 

CAU-

TION

 notice until the indi-

cated conditions are fully 
understood and met. 

WA R N I N G

A WARNING notice 
denotes a hazard. It calls 
attention to an operating 
procedure, practice, or the 
like that, if not correctly 
performed or adhered to, 
could result in personal 
injury or death. Do not pro-
ceed beyond a WARNING 
notice until the indicated 
conditions are fully under-
stood and met.

Earth (ground) terminal

Equipment protected 
throughout by double insula-
tion or reinforced insulation

Caution, risk of electric 
shock

Caution, risk of danger (refer 
to the instrument manual for 
specific Warning or Caution 
information)

For further safety information details, refer to the 

Keysight U1701B Dual Display Handheld Capacitance Meter User’s Guide

.

Summary of Contents for u1701b

Page 1: ...Keysight U1701B Dual Display Handheld Capacitance Meter Quick Start Guide ...

Page 2: ......

Page 3: ... Calibration If anything is missing or damaged please contact the nearest Keysight Sales Office For more detailed information please refer to the Keysight U1701B Dual Display Handheld Capacitance Meter User s Guide on Keysight Web site www keysight com find handheld tools WARNING To avoid damage to the device do not exceed the input limit Do not apply voltage to input terminals Discharge the capac...

Page 4: ...he meter and leads 3 Insert the capacitor legs into and input terminals respectively Ensure that the polarity of the capacitor s leg are correct 4 Remove your hands from capacitor to allow it to be tested 5 Read the measurement on the display CAUTION CAUTION To avoid possible damage to the meter or the equipment under test disconnect circuit power and discharge the capacitor before measuring capac...

Page 5: ...strument 2 SET Set high low limits for compare mode 3 REC Static recording mode 4 Compare mode 5 TOL Tolerance mode 6 REL Relative mode 7 HOLD SAVE Data hold To store the setting value into the memory 8 RANGE AUTO Manual range Auto range 9 HI LO High Low limits Backlight display 8 5 4 1 2 3 9 7 6 ...

Page 6: ... Up or Down to change the parameter 3 Press to select the digit to be adjusted the selected digit will flash 4 Press and hold for more than 1 s to save your setting 5 Press for more than 1 s to exit setup mode Features and Functions Actions Steps To power ON or OFF Press To enable data hold function Press To trigger holding next reading Press momentarily To exit data hold mode Press for more than ...

Page 7: ...not be set when an overload value exists REL annuciator will be displayed Press To renew the relative value Press again To exit relative mode Press for more than 1 s To select manual range and to turn off the AUTO annunciator Press To step up a range at a time Press again To select auto range In auto range mode the AUTO annunciator is displayed and the instrument will select an appropriate range f...

Page 8: ...has been used for compare mode The two right digits indicate current compare set The range from 01 to 25 The primary display shows the present measurement In this state it is ready for testing If the reading is beyond the high limit will be indicated will be indicated if the reading is out of the low limit The beeper will beep three times and the secondary display will indicate nGo If the reading ...

Page 9: ...ting mode a To select which digit to be adjusted b To increase or decrease the current digit s value c To select High or Low limit to be set d To store the setting value in the memory The beeper will beep twice if the selected value has been stored If the current setting do not meet the rule that the high limit must be equal or greater than the low limit the beeper will beep three times e To selec...

Page 10: ...d AS NZS CISPR11 2004 Safety Symbols CAUTION CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAU TION notice until the indi cated conditions are fully understood and met WARNING A WARNING notice denotes a h...

Page 11: ...This information is subject to change without notice Keysight Technologies 2009 2012 2014 Edition 3 August 2014 U1701 90047 U1701 90047 www keysight com ...

Reviews: