Keysight MIPI M-PHY Frame Generator User Guide
11
Test Instrument Setup
2
For system configurations with the M8040A, either a Keysight
M8045A-803 matched coupler pair or a 3dB attenuator should be
connected to the M8057 remote head output of the M8045 module. We
recommend using a 3dB attenuator with a minimum frequency range of
26.5GHz, 2 pieces for each data lane.
This configuration supports the Loopback and UniPro operating modes.
The Keysight M8046A analyzer module can be used to do loopback testing
with continuous patterns. However, it cannot be used to test bursts.
With the M8040A it is also possible to test two receiver channels of the
DUT simultaneously.
J-BERT BIT-3000 DSGA MIPI
®
M-PHY Generator
To use this setup, select “M8040A” as the “Instrument” in the Connection
window of the software and change “Low speed analyzer (DSGA)” to ON.
For more details, see
This system configuration (
) is recommended for the UniPro test
mode. In this case the DSGA is used to trigger the reset of the DUT and to
receive the frame and error counters, while the M8040A is used for the
DUT configuration and to generate the test pattern.
Figure 2
MIPI
®
M-PHY Frame Generator hardware setup for J-BERT
BIT-3000 DSGA
Summary of Contents for MIPI M-PHY
Page 1: ...User Guide Keysight MIPI M PHY Frame Generator ...
Page 5: ...Keysight MIPI M PHY Frame Generator User Guide 1 Introduction Overview 6 ...
Page 8: ...8 Keysight MIPI M PHY Frame Generator User Guide 1 Introduction ...
Page 18: ...18 Keysight MIPI M PHY Frame Generator User Guide 3 Software Installation and Update ...
Page 22: ...22 Keysight MIPI M PHY Frame Generator User Guide 4 Starting and Registering the Software ...
Page 70: ...70 Keysight MIPI M PHY Frame Generator User Guide 6 Software Installation and Update ...
Page 74: ...72 Keysight MIPI M PHY Frame Generator User Guide 7 Software Installation and Update ...
Page 75: ...Keysight MIPI M PHY Frame Generator User Guide 75 ...