Summary of Contents for U9397A

Page 1: ...Keysight U9397A C FET Solid State Switch SPDT Operating and Service Manual...

Page 2: ...e rights customarily provided to the public to use modify reproduce release per form display or disclose commercial computer software or commercial com puter software documentation No additional gover...

Page 3: ...hod 1010 8 Condition C modified Humidity Operating condition 50 to 95 RH at 40 C one 24 hour cycle repeated five times Storage condition 95 RH at 40 C five days Shock Half sine smoothed 1000 G at 0 5...

Page 4: ...ed as a Monitoring and Control Instrument product The affixed product label is as shown below Do not dispose in domestic household waste To return this unwanted instrument contact your nearest Keysigh...

Page 5: ...oduct category 4 Sales and Technical Support 4 1 General Information Product Overview 12 Features 13 Circuit Logic 14 2 Specifications Specifications 18 Physical Specifications 20 3 Operating Guide In...

Page 6: ...6 Keysight U9397A C Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 7: ...t of Figures Figure 1 1 U9397A C FET solid state switches 12 Figure 1 2 Block diagram on the operation of U9397A C FET solid state switches 14 Figure 2 1 Dimensions of U9397A C FET solid state switche...

Page 8: ...8 Keysight U9397A C Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 9: ...f FET solid state switches 12 Table 1 2 Switch operation logic 15 Table 2 1 RF specifications for U9397A C FET solid state switches 18 Table 2 2 Absolute maximum rating for U9397A C FET solid state sw...

Page 10: ...10 Keysight U9397A C Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 11: ...9397A C FET Solid State Switch SPDT Operating and Service Manual 11 1 General Information Product Overview 12 Circuit Logic 14 This chapter provides an overview of the Keysight U9397A C FET solid stat...

Page 12: ...lid state switches available The U9397A C is particularly suitable for measuring sensitive devices and components such as mixers and low noise amplifiers where video leakage may cause damage or reliab...

Page 13: ...nt damage to sensitive devices with low video leakage 10 mVpp Minimize crosstalk with exceptionally high isolation 100 dB at 8 GHz Maintain fast throughput with industry leading settling time for FET...

Page 14: ...h RF ports and the integrated TTL CMOS driver is configured in such a way that when either the RF1 or RF2 port is not selected to RFCOM it will be terminated to 50 Ohm as shown in Figure 1 2 Figure 1...

Page 15: ...General Information 1 Keysight U9397A C Operating and Service Manual 15 Table 1 2 Switch operation logic CTRL logic RFCOM to RF1 RFCOM to RF2 0 Low loss Isolated 1 Isolated Low loss...

Page 16: ...1 General Information 16 Keysight U9397A C Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 17: ...397A C FET Solid State Switch SPDT Operating and Service Manual 17 2 Specifications Specifications 18 Physical Specifications 20 This chapter provides the specifications of the U9397A C FET solid stat...

Page 18: ...cifications for U9397A C FET solid state switches Specification U9397A U9397C Frequency range 300 kHz to 8 GHz 300 kHz to 18 GHz Insertion loss 3 0 dB 300 kHz to 4 GHz 3 5 dB 4 GHz to 8 GHz 5 0 dB 300...

Page 19: ...witches a Operation in excess of any one of these may result in permanent damage to the products Min Max Unit RF input power average U9397A U9397C 29 27 dBm dBm DC voltage to RF port 2 5 2 5 V Current...

Page 20: ...Figure 2 1 illustrate the physical specifications of U9397A C FET solid state switches Figure 2 1 Dimensions of U9397A C FET solid state switches Table 2 3 U9397A C FET solid state switches physical s...

Page 21: ...DT Operating and Service Manual 21 3 Operating Guide Installation 22 Operating Instructions 23 Performance Tests 25 Service Instructions 25 This chapter describes the installation operating instructio...

Page 22: ...ontact the nearest Keysight Technologies Sales and Service office Refer to Sales and Technical Support on page 4 of this manual Keysight Technologies will arrange for repair or replacement of the dama...

Page 23: ...the solid state switch to be verified The S21 insertion loss measurement is the best way to determine if the switch is faulty by applying the appropriate logic to the CTRL pin Figure 3 1 Connection t...

Page 24: ...lustrated in Figure 3 1 2 Ensure that 24 Vdc and GND are connected 3 If RF1 of the switch is connected to Port 2 apply logic 0 to CTRL This should yield low loss from RFCOM to RF1 S21 should not excee...

Page 25: ...procedure in the analyzer s operating manual Service Instructions Adjustment The U9397A C FET solid state switches do not have internal adjustments and should not be opened Repair The U9397A C FET so...

Page 26: ...3 Operating Guide 26 Keysight U9397A C Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 27: ...is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2007 2017 Edition 4 August 30 2017 Printed in Malaysia U9397 90001 U9397 90001 w...