background image

Keysight U1701B Dual 

Display Handheld 

Capacitance Meter

 

Quick Start 

Guide

Summary of Contents for U1701B

Page 1: ...Keysight U1701B Dual Display Handheld Capacitance Meter Quick Start Guide ...

Page 2: ... adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNIN...

Page 3: ... anything is missing or damaged please contact the nearest Keysight Sales Office For more detailed information please refer to the Keysight U1701B Dual Display Handheld Capacitance Meter User s Guide on Keysight Web site www keysight com find handheld tools WARNING To avoid damage to the device do not exceed the input limit Do not apply voltage to input terminals Discharge the capacitor before tes...

Page 4: ...pacitance of the meter and leads 3 Insert the capacitor legs into and input terminals respectively Ensure that the polarity of the capacitor s leg are correct 4 Remove your hands from capacitor to allow it to be tested 5 Read the measurement on the display CAUTION To avoid possible damage to the meter or the equipment under test disconnect circuit power and discharge the capacitor before measuring...

Page 5: ...FF the instrument 2 SET Set high low limits for compare mode 3 REC Static recording mode 4 Compare mode 5 TOL Tolerance mode 6 REL Relative mode 7 HOLD SAVE Data hold To store the setting value into the memory 8 RANGE AUTO Manual range Auto range 9 HI LO High Low limits Backlight display 8 5 4 1 2 3 9 7 6 ...

Page 6: ...the non volatile memory even after the instrument is turned off To configure the related parameters on setup mode ensure that the following procedures are followed 1 Press Left or Right to select the menu item to be set 2 Press Up or Down to change the parameter 3 Press to select the digit to be adjusted the selected digit will flash 4 Press and hold for more than 1 s to save your setting 5 Press ...

Page 7: ...ction The beeper will beep when a new MAX or MIN value has been recorded The static recording captures stable values and updates the memory It will not record values that are overloaded OL or below 10 count value Press To cycle through maximum minimum average and present readings MAX MIN AVG or MAX AVG MIN annunciator will be turned on respectively to indicate which value is being displayed Press ...

Page 8: ...e than 1 s To select manual range and to turn off the AUTO annunciator Press To step up a range at a time Press again To select auto range In auto range mode the AUTO annunciator is displayed and the instrument will select an appropriate range for resolution if the reading is greater than the maximum available range OL will be displayed The instrument will select a lower range when the reading is ...

Page 9: ...ompare mode The two right digits indicate current compare set The range from 01 to 25 The primary display shows the present measurement In this state it is ready for testing If the reading is beyond the high limit will be indicated will be indicated if the reading is out of the low limit The beeper will beep three times and the secondary display will indicate nGo If the reading is within the high ...

Page 10: ...01 and the primary display will indicate the value of HI limit The following buttons will be used for this setting mode To select which digit to be adjusted To increase or decrease the current digit s value To select High or Low limit to be set To store the setting value in the memory The beeper will beep twice if the selected value has been stored If the current setting do not meet the rule that ...

Page 11: ...an 1 s Actions Steps CAUTION Degradation of some product specifications can occur in the presence of ambient electromagnetic EM fields and noise that affects the product s power line or I O cables The product self recovers and operates to all specifications when the source of the ambient EM field and noise is removed the product is protected from the ambient EM field or the product cabling is shie...

Page 12: ...12 Keysight U1701B Quick Start Guide ENGLISH THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...

Page 13: ...s subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2009 2012 2014 2017 Edition 4 July 1 2017 Printed in Malaysia U1701 90047 U1701 90047 www keysight com ...