7 Run Power Calibration
2. Calibrate the Cable signal path
a. Disconnect the power sensor from
S9101RH mmWave Transceiver connector
RF Tx/Rx 2
➁
.
b. Using an 8121-3222 cable, 2.4 mm (m) to 2.4 mm (m), 152.4 mm (6.0 in)
or equivalent, connect one end of the cable to the
S9101RH mmWave Transceiver connector
RF Tx/Rx 2
➁
.
c. Using an 11900B adapter, 2.4 mm (f) to 2.4 mm (f) or equivalent,
connect the U8487A Power Sensor or equivalent to the end of the cable.
d. Select
Ok
to continue the calibration.
View the
Results Cable
tab when the calibration is complete.
3. Calibrate the Receiver (Rx) signal path
a. Disconnect the power sensor and adapter from the cable.
b. Connect the free end of the cable to the
S9101RH mmWave Transceiver connector
RF Tx/Rx 1
➀
.
c. Select
Ok
to complete the calibration.
View the
Results Receiver
tab when the calibration is complete.
Corrections are stored in:
S9100ID_<SerialNumber>-
Rx-RFInputOutput1-CHANNELPOWER.csv