System-Related Operations
Though not directly related to output programming, the following functions also control instrument
operation.
Instrument Identification
You can query the model number, serial number, options, and firmware revision. SCPI commands
return information with the *IDN? and *OPT? queries.
Front Panel Menu Reference
SCPI Command
Select
System\About\Frame
.
To return manufacturer, model number, serial
number, and firmware revision:
To return the installed options:
Instrument State Storage
The power supply has ten storage locations in non-volatile memory to store instrument states. The
locations are numbered 0 through 9. Any state previously stored in the same location will be
overwritten.
Front Panel Menu Reference
SCPI Command
Select
States\SaveRecall
.
In the SaveRecall field, enter a location from 0 to 9.
Then press
Select
.
Select Save to save the state to Recall to recall a state.
To save a state in location 1:
To recall a state from location 1:
Specifying a power-on state
When shipped, the power supply is configured to automatically recall the reset (*RST) settings at
power-on. However, you can configure the power supply to use the settings you have stored in
memory location 0 at power-on.
Front Panel Menu Reference
SCPI Command
Select
States\PowerOn
.
Select Recall State 0. Then press
Select
.
Keysight RP7900 Series Operating and Service Guide
161
4 Using the Regenerative Power System
Summary of Contents for RP7900 Series