Step 5. Choose analysis bandwidth
Description
Option number Additional information
10 MHz/25 MHz analysis bandwidth
Standard
Useful for most cellular communications, wireless connectivity, and audio/video broadcasting
measurement applications; licensed as N9020A-B25
40 MHz analysis bandwidth
N9020A-B40
Extends the analysis bandwidth to 40 MHz
(Option MPB required for measurements at frequency > 3.6 GHz); included in B85, B1A, or
B1X; also enables fast sweep capability licensed as N9020A-FS1 and N9020A-FS2; if Option
BAA is installed, provides 40 MHz per channel baseband bandwidth
85 MHz analysis bandwidth
N9020A-B85
Extends the analysis bandwidth to 85 MHz
(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability
licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA
125 MHz analysis bandwidth
N9020A-B1A
Extends the analysis bandwidth to 125 MHz
(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability
licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA
160 MHz analysis bandwidth
N9020A-B1X
Extends the analysis bandwidth to 160 MHz
(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability
licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA
Microwave preselector bypass
N9020A-MPB
Required for wide analysis bandwidth measurements with Option B40, B85, B1A, or B1X
at frequency > 3.6 GHz; also enables fast sweep capability licensed as N9020A-FS1 and
N9020A-FS2
Step 6. Choose performance options
Description
Option number Additional information
Enhanced phase noise
Standard
1
Licensed as N9020A-EP2
Digital processor with 2 GB capture
memory
N9020A-DP2
Comes standard with Option B40, B85, B1A, or B1X; also enables fast sweep capability
licensed as N9020A-FS1 and N9020A-FS2
I/Q baseband inputs, analog
N9020A-BBA
Single-ended/differential, 50 Ω/1 MΩ impedance; not compatible with Option B85, B1A, or
B1X
External mixing
N9020A-EXM
Connects with Keysight and third party mixers to extend frequency coverage up to 1.1 THz;
single port
2
for LO out and IF in (SMA female)
Fast power
N9020A-FP2
Accelerates the power measurements such as ACPR; requires Option B40
Noise floor extension
N9020A-NFE
Improves analyzer's DANL performance (instrument alignment based processes); licensed as
N9020A-NF2
Time domain scan
N9020A-TDS
Improves scan speed for EMC pre-compliance tests; requires N6141A EMC pre-compliance
measurement application and Option DP2, or B40 (or wider bandwidth option)
Resolution bandwidth extended
N9020A-RBE
Extends the maximum RBW in Zero Span; requires option B85, B1A, or B1X
Step 7. Add real-time spectrum analysis
Description
Option number Additional information
Real-time analysis up to 160 MHz BW,
basic detection
N9020A-RT1
Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 17.3 μs
signal duration for 100% probability of intercept (POI); requires Option B85, B1A, or B1X,
which determines maximum real-time bandwidth; also supports Option EXM
Real-time analysis up to 160 MHz BW,
optimum detection
N9020A-RT2
Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 3.57 μs
signal duration for 100% probability of intercept (POI); requires Option B1X, B1A, or B85,
which determines maximum real-time bandwidth; also supports Option EXM
Real-time spectrum recorder and
analyzer application
N9020A-RTR
Enables recording, analyzing and playback of spectrum density data over time for detecting
and analyzing signal anomalies; requires Option RT1 or RT2
1. All instruments with serial number prefix ≥ MY/SG/US5233 are installed with the N9020A-EP2 standard for the enhanced phase noise performance. The
N9020A-EP2 is not upgradable.
2. When used with the Keysight 11970 Series external mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as
N9029AE13, or from OML Inc. as DPL313B.