Module installation procedures

Module installation procedures

1

Press down the ejector.

2

Slide the M9216A module into any slot until 
the backplane connectors touch.

3

Seat the M9216A module into the 
mainframe by pulling up the ejector.

4

Tighten the top and bottom screws to secure 
the M9216A module to the mainframe.

1

2

3

4

Summary of Contents for M9216A

Page 1: ...Keysight M9216A PXI High Voltage Data Acquisition Startup Guide...

Page 2: ......

Page 3: ...M9216A Startup Guide I...

Page 4: ...this document that conflict with these terms the warranty terms in the separate agreement shall control Restricted Rights Legend If software is for use in the performance of a U S Government prime con...

Page 5: ...possible wear cracks or breaks before each use When installing equipment where access to the main power cord is restricted such as rack mounting a separate main input power disconnect device must be p...

Page 6: ...U law as of August 13 2005 All electric and electronic equipment are required to be separated from normal waste for disposal Reference WEEE Direc tive 2002 96 EC This symbol indicates the time period...

Page 7: ...2 Inspect the module for damage 3 Return the module for service 4 Step 2 Verify the Shipment Contents 5 Step 3 Install the Software 6 System requirements 6 Power up the controller 8 Install the softw...

Page 8: ...VI M9216A Startup Guide...

Page 9: ...t com find M9216A Related documentation A softcopy of this Startup Guide and the documentation listed below can be found on the CD ROM that is shipped with this product You can also download them for...

Page 10: ...d at a static safe work station The following figure shows an example of a static safe work station using two types of ESD protection Figure 1 Static safe work station example CAUTION The M9216A is sh...

Page 11: ...must provide at least 1 of isolation from ground Inspect the module for damage After unpacking the M9216A carefully inspect the unit for any shipping damage Report any damage to the shipping agent im...

Page 12: ...tag and attach it to the malfunctioning equipment Name and address of owner A P O box is not acceptable as a return address Product model number for example M9216A Product serial number for example M...

Page 13: ...0001 contains software drivers and all product documentation in PDF format Printed copy of this document M9216A Startup Guide Calibration certificate NOTE Every PXI module is shipped with a Software a...

Page 14: ...ight IO Libraries Suite 1 5 GB available hard disk space includes 1 GB for Microsoft NET Framework 2 0 SP2 2 65 MB for Keysight IO Libraries Suite 1 5 GB available hard disk space includes 1 GB for Mi...

Page 15: ...8A chassis Softwares Keysight IO Libraries Suite 16 0 and above is required Adobe Reader version 6 0 or higher is required to view the provided PDF files 1 Because of the installation procedures less...

Page 16: ...s are located on the bundled CD M9216 10001 The same softwares are also available for free download at the Keysight website http www keysight com find M9216A This installation includes the following K...

Page 17: ...6A PXI High Voltage Data Acquisition M9216A Startup Guide 9 Figure 2 InstallShield Wizard for Keysight M9216A 3 After installation is complete power down the chassis and the host PC if using the remot...

Page 18: ...out cooling 4 If you are using an embedded controller proceed to step 5 If you using a remote controller skip to step 6 CAUTION The PXI hardware does not support hot swapping capabilities changing mod...

Page 19: ...e unlatched downward position Slide the module completely into the chassis When you begin to feel resistance push up on the injector ejector handle to fully inject the module into the chassis 6 If you...

Page 20: ...sary air circulation in the chassis 11 If you are using a remote controller connect the System Interface Card in the chassis to host computer 12 Plug in and power up the PXI chassis 13 If you are usin...

Page 21: ...procedures Module installation procedures 1 Press down the ejector 2 Slide the M9216A module into any slot until the backplane connectors touch 3 Seat the M9216A module into the mainframe by pulling u...

Page 22: ...sight Connection Expert KCE by clicking its desktop shortcut icon or by clicking Start All Programs Keysight IO Library Suite Keysight Connection Expert The KCE will display all modules that are conne...

Page 23: ...correctly installed in the mainframe If using an external host PC and PCI bus extender system verify that the mainframe power is turned on Ensure that the mainframe is powered on before the PC control...

Page 24: ...ails on how to use the SFP please refer to the Keysight M9216A Soft Front Panel Help document When successful the M9216A SFP dialog box will appear By default the M9216A will be started in Multiple Ch...

Page 25: ...e digitizer channel a stable DC source preferably with low noise is required A multimeter can also be used to provide a second verification of the voltage If you intend to verify that the M9216A meets...

Page 26: ...18 M9216A Startup Guide Keysight M9216A PXI High Voltage Data Acquisition Figure 7 M9216A front panel layout of the input and auxiliary ports...

Page 27: ...and are able to acquire waveforms You may repeat the steps outlined below to verify all eight digitizer channels in the M9216A For verification purpose the M9216A will be used in Multiple Channel Meas...

Page 28: ...ted up if not please set the measurement mode to Multiple Channel Note that a hardware reset will occur when switching the measurement mode By default all input ports will be configured with a Record...

Page 29: ...to the M9216A hardware Note that the relays of the M9216A input port multiplexer require about 1 millisecond to settle After steps A and B the SFP dialog should look similar to Figure 9 In Figure 9 In...

Page 30: ...age measured with a multimeter Verifying the auxiliary output ports To verify that the M9216A multiplexer is functioning the input ports are switched to the auxiliary output ports The resistance betwe...

Page 31: ...tiplexer for Bank 1 Table 2 Connection logic of Bank 1 Channel 1 Aux11 Primary Aux12 Complementary Always Connected Port 1 Port 17 Port 9 Port 25 Port 17 Port 1 Port 25 Port 9 Channel 1 Aux21 Primary...

Page 32: ...e input ports of Channel 2 are able to be switched to the auxiliary output ports To route the input ports to auxiliary output tick the check box Bank 2 Aux Out in the Auxiliary Settings To select a po...

Page 33: ...e auxiliary output ports Step C Use a multimeter to measure the resistance between the input ports and auxiliary ports For example if input port 18 of Channel 2 was switched to the auxiliary output po...

Page 34: ...26 M9216A Startup Guide Keysight M9216A PXI High Voltage Data Acquisition...

Page 35: ...tel 31 20 547 2111 Japan tel 81 426 56 7832 fax 81 426 56 7840 Korea tel 080 769 0800 fax 080 769 0900 Latin America tel 305 269 7500 Taiwan tel 0800 047 866 fax 0800 286 331 Other Asia Pacific Count...

Page 36: ...This information is subject to change without notice Keysight Technologies 2011 2014 Edition 2 November 2014 M9216 90001 M9216 90001 www keysight com...

Reviews: