:SBUS<n> Commands
27
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
787
:SBUS<n>:CXPI Commands
NOTE
These commands are valid when the CXPI (Clock Extension Peripheral Interface) serial decode
and triggering option has been licensed.
Table 105
:SBUS<n>:CXPI Commands Summary
Command
Query
Options and Query Returns
:SBUS<n>:CXPI:BAUDrat
e <baudrate> (see
:SBUS<n>:CXPI:BAUDrat
<baudrate> ::= integer from 9600
to 40000 in 100 b/s increments.
:SBUS<n>:CXPI:PARity
{{0 | OFF} | {1 |
ON}} (see
:SBUS<n>:CXPI:PARity?
{0 | 1}
:SBUS<n>:CXPI:SOURce
<source> (see
:SBUS<n>:CXPI:SOURce?
<source> ::= {CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
:SBUS<n>:CXPI:TOLeran
ce <percent> (see
:SBUS<n>:CXPI:TOLeran
<percent> ::= from 1-30, in NR1
format.
:SBUS<n>:CXPI:TRIGger
<mode> (see
:SBUS<n>:CXPI:TRIGger
<mode> ::= {SOF | EOF | PTYPe |
ID | DATA | LDATa | CRCerror |
PARityerror | IBSerror | IFSerror
| FRAMingerror | DLENgtherror |
SAMPleerror | ALLerrors |
SLEepframe | WAKeuppulse}
:SBUS<n>:CXPI:TRIGger
:IDFilter {{0 | OFF}
| {1 | ON}} (see
:SBUS<n>:CXPI:TRIGger
:IDFilter? (see
{0 | 1}
:SBUS<n>:CXPI:TRIGger
:PTYPe {{0 | OFF} |
{1 | ON}} (see
:SBUS<n>:CXPI:TRIGger
:PTYPe? (see
{0 | 1}
:SBUS<n>:CXPI:TRIGger
:PATTern:DATA
<string> (see
:SBUS<n>:CXPI:TRIGger
:PATTern:DATA? (see
<string> ::= "nn...n" where n ::=
{0 | 1 | X}
<string ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X}
:SBUS<n>:CXPI:TRIGger
:PATTern:DATA:LENGth
<length> (see
:SBUS<n>:CXPI:TRIGger
:PATTern:DATA:LENGth?
<start> ::= integer between 0 and
12, in NR1 format.