background image

Keysight B2900A Series 
Precision Instruments

The B2900A series lines  

up products for both  

precision source and  

precision measurement.

www.keysight.com/find/b2900a

myKeysight

www.keysight.com/find/mykeysight

A personalized view into the information most relevant to you.

www.axiestandard.org

AdvancedTCA

®

 Extensions for Instrumentation and Test (AXIe) is an 

open standard that extends the AdvancedTCA for general purpose and 
semiconductor test. Keysight is a founding member of the AXIe consortium. 
ATCA

®

, AdvancedTCA

®

, and the ATCA logo are registered US trademarks of 

the PCI Industrial Computer Manufacturers Group. 

www.lxistandard.org

LAN eXtensions for Instruments puts the power of Ethernet and the 
Web inside your test systems. Keysight is a founding member of the LXI 
consortium.

www.pxisa.org

PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a 
rugged, PC-based high-performance measurement and automation system.

Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty

Keysight’s commitment to superior product quality and lower total cost 
of ownership. The only test and measurement company with three-year 
warranty standard on all instruments, worldwide.

Keysight Assurance Plans
www.keysight.com/find/AssurancePlans

Up to five years of protection and no budgetary surprises to ensure your 
instruments are operating to specification so you can rely on accurate 
measurements.

www.keysight.com/go/quality

Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008  
Quality Management System

Keysight Channel Partners
www.keysight.com/find/channelpartners

Get the best of both worlds: Keysight’s measurement expertise and product 
breadth, combined with channel partner convenience.

www.keysight.com/find/precisionSMU

For more information on Keysight 
Technologies’ products, applications or 
services, please contact your local Keysight 
office. The complete list is available at:
www.keysight.com/find/contactus

Americas 

Canada

(877) 894 4414

Brazil

55 11 3351 7010

Mexico

001 800 254 2440

United States

(800) 829 4444

Asia Pacific

Australia

1 800 629 485

China

800 810 0189

Hong Kong

800 938 693

India

1 800 112 929

Japan

0120 (421) 345

Korea

080 769 0800

Malaysia

1 800 888 848

Singapore

1 800 375 8100

Taiwan

0800 047 866

Other AP Countries

(65) 6375 8100

Europe & Middle East

Austria

0800 001122

Belgium

0800 58580

Finland

0800 523252

France

0805 980333

Germany

0800 6270999

Ireland

1800 832700

Israel

1 809 343051

Italy

800 599100

Luxembourg

+32 800 58580

Netherlands

0800 0233200

Russia

8800 5009286

Spain

800 000154

Sweden

0200 882255

Switzerland

0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)

United Kingdom

0800 0260637

For other unlisted countries:
www.keysight.com/find/contactus

(BP-09-23-14)

10 | Keysight | Detailed Demonstration Guide: Making Resistance Measurement Using SMU - Demonstration Guide

This information is subject to change without notice.
© Keysight Technologies, 2014
Published in USA, August 4, 2014
5991-4247EN

www.keysight.com

Summary of Contents for B2901A

Page 1: ...Keysight Technologies Detailed Demonstration Guide Making Resistance Measurement Using SMU Keysight B2901A 02A 11A 12A Precision Source Measure Unit Demonstration Guide...

Page 2: ...plication software that make it easy for you to begin making productive measure ments immediately This demonstration guide shows how easily basic resistance measurement can be made using the Keysight...

Page 3: ...ed tweezers 4 Clip the other lead of 1 k Resistor with the red gold plated tweezers Demonstration 1 Change View mode to Single View a Press repeatedly until Single View for Channel 1 is shown in the d...

Page 4: ...o stop making measurements periodically 3 Turn off the channel output a Press Ch1 to turn off Channel 1 Output relay LAB 1 Make a Resistance Measurement continued Measurement parameters are updated pe...

Page 5: ...Resistor with black gold plated tweezers Why is 4 wire connection required For very low resistance measurements where the residual lead resistance is comparable to the DUT resistance the 2 wire measu...

Page 6: ...wire connection you can see the status indicator on GUI as below although no indicator can be seen on being configured to use 2 wire connection Demonstration 1 Reset the instrument a Press and then pr...

Page 7: ...nd select and then press to configure to use 4 wire connection c Press then press to set Channel 1 V I Source Function to I Source If can t be found on the Assist keys press to change the keys d Press...

Page 8: ...asure condition and calculates the resistance value e Press and set Channel 1 Limit value to 1 V f Rotate to select Resistance measurement operation and press to edit it Then press to set Resistance m...

Page 9: ...connection is 1 6 Ohm The difference that is 0 6 Ohm should be the residual lead resistance on the measurement cables LAB 2 Make an Accurate Low Resistance Measurement continued 3 Press OK 2 Press 2 W...

Page 10: ...rely on accurate measurements www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2008 Quality Management System Keysight Channel Partners www keysight com find channelpartn...