Calibration Sequence
Do not attempt to calibrate the treadmill unless an Error Code is present. See Error Messages (page 21).
Our treadmill is equipped with a software package that will perform a calibration sequence unique to your
specific model number.
Please perform the following steps to calibrate the
HEALTH TRAINER 502t TREADMILL.
1. Unplug power cord from outlet strip.
2. Attach Safety Key to console.
3. Plug power cord into outlet strip.
4. Initiate calibration sequence. Locate hole on the back of the console and insert the eraser end of a pencil
through the hole and press the calibration switch
twice
. As show on page 18.
5.
CL21
should appear in the Time window, if not, continue to press the calibration switch until CL21
appears.
Note:
During the calibration sequence, the Time window will display which step you are at in the process
(C21, C22, C23 and so on). The CAL/DIST window will display which key should be entered next. For exam-
ple, “E” for Enter, “P” for Power, or “SS” for Start / Stop.
6.
CL21:
MPH or KPH will be flashing in the Speed window, pressing the Speed +/ - button will toggle
options. Choose
MPH
(KPH), press Enter.
7.
CL22:
8, 10, or 12 (13, 16, or 20 in KPH mode) will be displayed in the Speed window, pressing the Speed
+/ - button will toggle options. Choose
10
(or 16 for KPH mode), press Enter.
8.
CL23:
FFF, UUU, or HHH will be displayed in the Speed window, pressing the Speed +/ - button will tog-
gle options. Choose
UUU
, press Enter.
9.
CL24:
111 or 222 will be displayed in the Speed window, pressing the Speed +/ - button will toggle
options. Choose
222
, press Enter.
10.
CL25:
AL1 or AL2 will be displayed in the Speed window, pressing the Speed +/ - button will toggle
options. Choose
AL2
, press Enter.
11.
CL26:
OPA or OPI will be displayed in the Speed window, pressing the Speed +/ - button will toggle
options. Choose
OPA
, press Enter.
12.
CL27:
Blank (nothing), “a”, “b”, “c”, or “d” will be displayed in the Incline window, pressing the Speed
+/ - button will toggle options. Choose
Blank
, press Enter.
13. CAL/DIST window will display “
E”
, Press Enter. “
55”
will display in CAL/DIST window.
14. Press Start/ Stop.
15. At this time, make sure you are not standing on the walking belt, as the machine will automatically initiate
belt movement and run through a complete calibration and diagnostic routine.
Press
Enter
, belt will begin to move, unit will begin self-calibration.
16. When Speed and Incline calibration has finished, press Power button
twice
, display should blank, and
treadmill should be ready for use.
T
o avoid possible damage to the treadmill and the possibility of injury, do not operate the treadmill
until the problem is corrected. Call Keys Customer Service at (888) 340-0482.
22
Summary of Contents for HealthTrainer 502t
Page 26: ...Exploded View 26...