background image

KL/RX2 
Master Control Panel

230v

Remote 
Control

Rain Sensor

MASTER 

CONTROL 

PANEL

KL/Rx2

Motor 2

Motor 1

Blind 1

Blind 2

24v

24v

KL/RX2 MAXIMUM OPERATIONAL 
CAPACITY IS 2 MOTORS & 2 BLINDS
*NOT AVAILABLE FOR 4 MOTORS*

24v

24v

Transformer

24v

MAINS 
SUPPLY

KL/RX2-2012G

Kit Contents: KL/RX2 Master Control Panel, 24v 2.7A Power Supply, 
 

 

    Rain Sensor, Remote Control

Summary of Contents for KL/RX2

Page 1: ...PANEL KL Rx2 Motor 2 Motor 1 Blind 1 Blind 2 24v 24v KL RX2 MAXIMUM OPERATIONAL CAPACITY IS 2 MOTORS 2 BLINDS NOT AVAILABLE FOR 4 MOTORS 24v 24v Transformer 24v MAINS SUPPLY KL RX2 2012G Kit Contents KL RX2 Master Control Panel 24v 2 7A Power Supply Rain Sensor Remote Control ...

Page 2: ... BE CARRIED OUT BY A QUALIFIED ELECTRICIAN THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED WIRING OF THE MASTER CONTROL WINDOWS BLIND CONNECTIONS RAIN SENSOR WARNING ONLY TO BE CONNECTED BY A QUALIFIED ELECTRICIAN 4 core cable from motor BROWN WHITE YELLOW GREEN Discard YELLOW GREEN cores All cables are to be a minimum of 0 75mm cable RAIN SENSOR FACTORY FITTED TO WINDOW Fig A Fig B ...

Page 3: ...he window s This will operate W and W on OUTPUTS 1 2 simultaneously Button 2 on the remote control will OPEN the blind s This will operate B and B on OUTPUTS 1 2 simultaneously and can be stopped at any point by pressing button 2 Button 4 on the remote control will CLOSE the blind s This will operate B and B on OUTPUTS 1 2 simultaneously REMOTE CONTROL OPERATION The KL RX2 control panel can be use...

Page 4: ...W and W need to be reversed 5 The rain sensor does not operate Please ensure that the wires connected to the rain sensor connector are correct and are made with a secure connection FOR THE LATEST TROUBLE SHOOTING GUIDE PLEASE REFER TO http keyliteroofwindows com downloads KL RX2 2012G THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN THE GUARANTEE WILL BE VOIDED IF THI...

Page 5: ...window can be closed automatically or by a remote switch 4 We recommend only a suitably qualified electrician should install and connect all electrical devices INSTALLATION PROCEDURES KL RX2 2012G THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED MOTOR INSTALLATION If the interior ceiling is not finished the cable ca...

Page 6: ...onnected and fitted at this stage Please follow wiring diagram supplied with your kit 3 Attach the motor mounting bracket to the latch keep timber using 4 No 25mm screws fig 4 Centre the bracket on either side of the latch keep 4 Latch Keep Timber Plug the cable into the motor ensuring that it is fully connected fig 5 NB If your kit contains a remote control it should be programmed at this stage P...

Page 7: ... not to fit a wall mounted switch you will then have to activate it using your remote control 7 Once the chain is fully extended use the connector bar to attach the chain to the vent flap bracket Ensuring that you keep the chain straight line up the vent flap bracket as shown fig 8 and mark 8 Drill a 5mm hole through the vent flap fig 9 9 Attach the vent flap bracket using 1 No 16mm bolt and dome ...

Page 8: ...www keyliteroofwindows com ...