background image

 

Seite 11

 

Press # to start. All doors in the system will now open and close after 

each other. 

TIP:

 It is a good idea to use this function when new cabinets are 

installed in the system. All doors are then tested and you know that the 

system is correctly installed. 

 

9 - Open cabinet with user code 

To open a cabinet simply enter the user code followed by #. 

 

10 - Reset - Factory settings 

To return to factory settings. All previous programming will be deleted. 

Press # to confirm. 
If you have forgotten the service code you need to make a total reset 

of the cabinet. 
1.  Turn off the power to the cabinet, battery back up as well if the 

cabinet has one. 

2.  Press * and # on the keypad and turn the power on again. 
3.  When the display is starting up, the cabinet is in factory mode and 

you can now start over the programming with the service code, 

301042# 

 

9. Technical data 

Mains voltage:

 

230 V, 50 Hz

 

Usage:

 

Stand-By: 0.5 W

 

 

Working: 12 W

 

CPU:

 

Microprocessor

 

Meomory:

 

EEPROM, Codes remain in the event of a 

power failure.

 

Lock:

 

Electron magnet 12V, 1A

 

Material:

 

Steel plate 1.5 mm

 

Surface:

 

Galvanized sheet metal, powder coated

 

Size:

 

HxWxD: 280 x 350 x 93 cm

 

Weight:

 

Approx. 6,0 kg

 

 

 

Summary of Contents for 9000 Series

Page 1: ...Seite 1 USER MANUAL Keybox Safe Art Code 9201 00018 9201 00019 Extension Art Code 9201 00020 ...

Page 2: ...g 3 5 Codes set on delivery 4 6 User menus 4 7 Display 5 8 Programming 6 8 1 Codes 6 8 2 Analysis 8 8 3 Load settings 9 8 4 Save log 9 8 5 Language 9 8 6 System 10 9 Technical data 11 10 PCB layout 12 11 Extensions 13 12 Technical data extensions 13 13 PCB layout extensions 14 14 Service and support 14 ...

Page 3: ...Directive The tests are carried out as specified in standard EN 60950 and checked according to EMC Standards En 50081 1 and EN 50082 1 3 Connection of 230 V power cable KeyBox is always supplied as Plug and Play as standard This means that all you have to do is to connect the cable supplied in the lower edge of the cabinet s left side Where this is not required a power cable is supplied that is in...

Page 4: ...ning to the factory setting See also under chapter 8 6 option 9 User codes No user codes are set on delivery 6 User menus When operating KeyBox and programming codes the user is guided by the display menu for Plus version All keypad buttons characters and are clearly indicated in each menu and window Log into the user menu with your service code 301042 on delivery Main menu Function menu 1 Codes 0...

Page 5: ...splay window and the menu instructions Line 1 Shows current position Line 2 For programming Line 3 For programming Line 4 Instructions for programming Use the following commands on line 4 To move upwards in the menu go back through the windows and correct mistakes 0 To go back to start position in the main menu To move down in the menus go forward through the windows to confirm a selection When an...

Page 6: ...e required option in the main menu 8 1 Codes New Code Enter current service code and press Enter 1 CODES Enter 1 NEW CODE Enter code 1 7 characters and press Enter compartment no and press twice NB If more compartments are required press once and then select the next compartment for which you want the code to apply On completion finish off with Enter name 1 12 characters and press Enter how many t...

Page 7: ... steps Remove code Enter current service code and press Enter 1 CODES Enter 2 REMOVE CODE Enter code 1 7 characters and press The message CODE ERASED is shown in the display To remove more codes enter code and press Press to go back to menu Display codes Enter current service code and press Enter 1 CODES Enter 3 DISPLAY CODE All codes in the cabinet are now displayed here Press 0 to move back in t...

Page 8: ...U SURE Press to confirm and 0 to cancel 8 2 Analysis Analysis is an effective and flexible tool It is then simple to view the event log directly in the display via the selections you make You can select whether to view events sorted by date time name or specific door You select yourself which parts you want to use for your search The more options you select the more specific analysis you receive 8...

Page 9: ...is is used only with the KeyWin Light software When you have inserted the USB memory in the cabinet Go into the menu and select LOAD SETTINGS and all information will be transferred to the cabinet 8 4 Save Log NB This is used only with the KeyWin Light software When you have inserted the USB memory in the cabinet Go into the menu and select SAVE LOG and all events will be saved to the USB memory 8...

Page 10: ...e to enter their codes after each other to open the door E g Person 1 has access to all compartments 1 6 Person 2 only has access to compartment 1 This means that they can only open compartment Access is always controlled by the person with the lowest authorization 6 Alarm Activate alarm Press to confirm For information about connecting to the circuit board see chapters 11 and 14 TIP Make sure to ...

Page 11: ...you have forgotten the service code you need to make a total reset of the cabinet 1 Turn off the power to the cabinet battery back up as well if the cabinet has one 2 Press and on the keypad and turn the power on again 3 When the display is starting up the cabinet is in factory mode and you can now start over the programming with the service code 301042 9 Technical data Mains voltage 230 V 50 Hz U...

Page 12: ...Seite 12 10 PCB layout ...

Page 13: ... system can be expanded with a Key Box Extension A total of 15 extension cabinets can be connected to a main cabinet 12 Technical data extension Lock Electron magnet 12V 1A Material Steel plate 1 5 mm Surface Galvanized sheet metal powder coated Size HxWxD 280 x 350 x 93 cm Weight Approx 3 6 kg ...

Page 14: ...ension 14 Service and Support EICHNER Organisation GmbH Co KG Postfach 15 38 D 96405 Coburg Uferstraße 28 D 96450 Coburg Telefon 0 95 61 27 07 0 Telefax 0 95 61 27 07 29 27 E Mail info eichner org de Internet www eichner org com ...