2.4 Connection of a
MECHANICAL BRAKE
2 3 4 5 6
Herewith you can see the connection of a 230V mechanic brake. Use
DIP 6
to setting up the brake.
If is necessary put in
ON DIP4
as shown in the picture:
15 16
2 5 6 7 6
2 5 6 7 6
Use DIP 6 to setting up the brake:
Put the
DIP6
in
ON
if the brake will be powered.
Put the
DIP6
in
OFF
when the brake has no
tension
2.5 Connection of the
LIMIT SWITCHES
Herewith you can see the connection of the limit switches.
Even if the working time can be programmed, limit switch
have to be programmed.
17 18 19
MOT 1
OPEN
CLOSE
The contact of the limit
switches are normally
closed (N.C.)
24 V
24 V
COM
COM
2.6 Connection of the
PHOTO-BEAMS
(inverting only when closing)
The photocell receiver contact must be:
-
clean
(insulated from power supply voltages)
-
N.C. type
(normally closed).
If more than one pair of photocells is used, they must
be connected in series.
If the PHOTO input is not used,
make a link between terminal
board 20 and COM.
POWER SUPPLY TO
TX PHOTOCELLE
POWER SUPPLY TO
RX PHOTOCELL
17 18 19 20
24 V
24 V
COM
COM
Photocell receiver.