4
EN
Important information, please read!
Technical speci
fi
cations
– Flow at 3 bar pressure:
approx. 6 l/min
– Pressure:
min. 0.5 bar/recommended 1-5 bar
– Operating pressure
max. 10 bar
– Test pressure:
16 bar
– Recommended hot water inlet temperature:
max.
65°C
– Water connection:
cold = blue marking
hot = red marking
Avoid pressure di
ff
erences between the cold and
hot water feeds.
Install a pressure reducer for static pressures
above 5 bar.
Installation dimensions,
refer to page 2
Installation,
refer to picture 1 on page 1
Flush potable water pipes thoroughly before and
after installation (observe EN 806 and 1717, as
well as DIN 1988).
Test connections for leaks with water pressure.
Operation,
refer to picture 5 and 6 on page 13
Servicing
, refer to picture 7 and 8 on page 13
Assemble in reverse order.
– Cartridge nut torque:
8 Nm
For spare parts with order numbers,
refer to page 15.
For warranty and care information please refer to
the attached
warranty and care instructions
.
These instructions are for both the installer for
installation and the user for operation and main-
tenance of the product. After installation, please
hand them over to the user to keep.
Symbols and explanations
Attention!
Warning against bodily injury or
damage to property.
Note, tip or reference
Incorrect installation
Correct installation/test of functionality
Observe installation details
Cold water
Hot water
Water
fl
ow
No water
fl
ow
Intended use
Single lever mixer tap for use in bathrooms and
WCs. Operation possible with pressure tanks and
thermally and hydraulically controlled instanta-
neous water heaters. Operation with unpressuri-
sed tanks (open water heaters) is
not
possible!
Operation only with potable water.
Product is only suitable for installation indoors!
Attention!
Only install in frost-free places.