Kett Riceter fg529 Operating Manual Download Page 5

3

 

Part Names

Note : Application table differ depending on the model number.

“POWER” button
“SELECT” button

Display

Handle stop red mark

Model No.

“MEA.” button (Measure)
“AVG.” button (Average)

Testing Chamber

Handle

Summary of Contents for Riceter fg529

Page 1: ...Grain and Seed Moisture Tester Riceter fg529 Operating Manual...

Page 2: ...ter fg500 series This tester can measure the moisture of grain by simple op eration but proper operation is necessary for accurate moisture measure ment Please read this operating manual carefully bef...

Page 3: ...1 Contents of Package 2 Part Names 3 Description of Display 4 How to Place Batteries 6 Before Measurement 7 Measurement 8 Average Value 18 Storage 19 Specifications 20 Table of contents...

Page 4: ...tents of Package Maize mill Operating manual Rice husker TR 130 Carrying case Sample tray 2 pcs Spoon with tweezers Cleaning brush Battery AA sizex4 pcs Inspection certificate Riceter J m f checker Op...

Page 5: ...3 Part Names Note Application table differ depending on the model number POWER button SELECT button Display Handle stop red mark Model No MEA button Measure AVG button Average Testing Chamber Handle...

Page 6: ...ally turned off in approx 5 minutes after turning on the power if no operation is performed Use of backlight in the display section allows users to see the display clearly even in the dark Battery Ind...

Page 7: ...ell below the lower limit of the measurement range or the contact between the test sample tray and the measuring unit of the main body was poor Error mark Main unit temperature is too low 5 C or lower...

Page 8: ...t the batteries from under the battery holder Open the battery box on the back side of the main unit and place 4 batteries appropriately How to Place Batteries Note Rice husker TR 130 is included not...

Page 9: ...re gradually discharging even when the tester is not used It is recommended to always use new batteries Place batteries in the correct polarity Riceter fg500 series is equipped with a temperature comp...

Page 10: ...s the POWER button All the characters and marks on the display section as well as the backlight light up for 2 seconds and then model number and software version number are automatically displayed The...

Page 11: ...n d Application Times are displayed It is ready for measurement Measurement Press the SELECT button and repeat until the abbreviation for the name of the application you wish to test appears The sele...

Page 12: ...eat Jute seed Parboiled rice and Atap rice See page 13 3 B for Maize milled Lentil Mustard Sesame Chili Black cumin and Onion See page 13 3 C for Mung bean and Black gram See page 14 3 D for Grass pea...

Page 13: ...evenly in one layer on the sample tray Note Both the amount of sample is too much or insufficient may cause a measurement error Over more too much sample may cause wear on the screw and damage the in...

Page 14: ...e one cup of sample by using the spoon with tweezers and put it on sample tray Note The milling operation of Maze is included in the attached manual 3 B 1 Mung bean and Black gram Take one and a half...

Page 15: ...move the handle insert the sample tray into the testing chamber until the guide line is hidden place 5 to 6 pieces of grain through the threaded opening in the front of the unit and attach the handle...

Page 16: ...g chamber and insert it into the testing chamber until the guide line is hidden Note Failure to observe this may cause the tip of the handle to damage the plastic portion of the sample tray Be sure to...

Page 17: ...e MEA button the decimal point blinks the backlight lights up the moisture content and measuring number are displayed thereafter The backlight goes out after 4 seconds but the moisture content remains...

Page 18: ...The measuring count alsochangesatthesametime 7 After a lapse of 5 minutes the power is automatically turned off and all the displayed items are cleared Pressing the POWER button while the display is i...

Page 19: ...e after every measurement If the last test sample remains proper measurement cannot be performed For continuous measurement disconnect the handle and remove the attached sample and contamination from...

Page 20: ...btain the average value of m o i s tu r e co nte nt s p r e ss th e AVG button within 5 minutes after measurement After the last measured value disappears the average calculation function does not wor...

Page 21: ...lean every portion of the main body in a careful manner Especially for the measuring unit disconnect the handle and clean the inner contact section sufficiently Be sure to put the tester together with...

Page 22: ...STA 103 C 4 5g whole 17hrs 7 Maize M A I Z 9 0 30 0 0 5 9 20 BG DAE 135 C 2g grinding 1hr 8 Parboiled rice P E R B 9 0 20 0 0 5 9 20 BG DAE 135 C 2g grinding 1hr 9 Atap rice A T A P 9 0 20 0 0 5 9 20...

Page 23: ...2 Reference method 16 Oil seeds Mustard seed MUST 5 0 18 0 1 5 5 18 ISO 665 2000 E 103 C 5 10g whole constant 3 hrs 17 Sesame S E S A 5 0 18 0 1 5 5 18 ISO 665 2000 E 103 C 5 10g whole constant 3 hrs...

Page 24: ...20 moisture range of sample Power source 1 5V AA size battery x 4 Auto power off 5 min after nothing of operation Power consumption Max 0 3W Dimensions and weight 164 W x 94 D x 64 5 H mm 0 44kg appro...

Page 25: ...23...

Page 26: ......

Page 27: ......

Page 28: ...cted in this user manual may not ap pear exactly as their actual counterparts but this does not affect their operation or functionality This user manual was intended to be written as clearly and accur...

Reviews: