background image

Installation

WARNING:

 Shock Hazard. May result in serious injury or death. Before physical mounting, turn OFF electrical 

power to all circuit breakers feeding into the panel before installing or servicing this product.

STEP 1

Determine Product Location 

1.  Identify the location of each LS0 luminaire. Each segment box in a run will be labeled and numbered in the 

order of the run layout. i.e., Segment #1 of 3, Segment #2 of 3, Segment #3 of 3 in a run with 3 segments.

2.  Locate wiring holes for LS0 luminaire.

3.  Determine location for X96 controller. Measure the length from the controller to the first luminaire and cut your 

4-conductor cable to length. Since this a low-voltage wire, conduits are not required. 

4.  Ensure that there are enough adapters to complete your wiring. The X96 controller only comes with one 

adapter to connect to the first LS0 segment. Extra adapters must be purchased separately.

STEP 2

Install Mounting Brackets

1.  LS0 segments attach to the mounting brackets on the underside of the fixture. Determine location of mounting 

brackets based on the center line of the segments.

2.  Mount brackets to the surface with screws. 

3.  When screwing mounting brackets to the surface, do not over tighten the screws. The bracket should be snug 

to the surface but the bracket should be able to rotate, and slide back and forth.

continued on next page

8 | 

LS0

 INSTALLATION GUIDE

P/N 3662562 Rev A

© 2021 Lutron Electronics Co., Inc. All rights reserved.

Summary of Contents for CM-LS0

Page 1: ...LS0 LOW VOLTAGE LINEAR Installation Guide Models CM LS0 HW LS0...

Page 2: ...xample System Connection 10 Troubleshooting 10 Warranty Tech Support 11 Risk of electric shock Use in dry or damp locations only Turn power OFF at circuit breaker or remove fuse Damage to this product...

Page 3: ...ntroller 15 ft 4 6 m 15 ft 4 6 m 24 ft 7 3 m Input Current 0 259 A ft 0 259 A ft 0 161 A ft Input Voltage 21 V 21 V 21 V Flexible Connector input and Straight Connector output Available in custom orde...

Page 4: ...A Adapter Type B Screws Mounting Bracket Right Angle End Covers Other System Components ordered separately X96 Ketra Controller 4 wire cable ex QSH CBLP M 500 4 LS0 INSTALLATION GUIDE P N 3662562 Rev...

Page 5: ...ire a dedicated enclosure Notes The X96 Ketra controller provides low voltage power and communication to the LS0 luminaires The X96 needs to be between the AC mains power source and the run of LS0 lin...

Page 6: ...parallel wiring installations are not supported 120 277 V 60 Hz Mains Supply DO NOT WIRE IN PARALLEL 120 277 V 60 Hz Mains Supply 6 LS0 INSTALLATION GUIDE P N 3662562 Rev A 2021 Lutron Electronics Co...

Page 7: ...products backwards 50 ft 15 2 m total cable run max from controller to last segment A typical run installation includes X96 controller 4 conductor cable 16 AWG or 12 AWG 1 5 mm2 or 3 5 mm2 ex QSH CBLP...

Page 8: ...nductor cable to length Since this a low voltage wire conduits are not required 4 Ensure that there are enough adapters to complete your wiring The X96 controller only comes with one adapter to connec...

Page 9: ...on the cables and connections STEP 4 Connect to Controller See 3662581 install guide on how to install the X96 controller 1 Connect your 4 conductor cable to the Type A adapter Ensure you are followin...

Page 10: ...tput and 24 ft 7 3 m for long run Verify power connections red and black on QSH CBL M 500 are wired correctly on the X96 controller and each luminaire adapter Magenta LS0 is installed backwards Discon...

Page 11: ...questions and technical support please contact 844 588 6445 ketrasupport lutron com Ketra is a trademark or registered trademark of Lutron Electronics Co Inc in the US and or other countries 11 LS0 I...

Page 12: ...6231 E Stassney Ln Bldg 13 Suite 400 Austin TX 78744 www ketra com 512 872 4349 P N 3662562 Rev A...