Kestrel 4200 Instruction Manual Download Page 2

7

7

 

Chart

 - Displays a graphical representation of up to 1600 stored data points for each measurement.  

 

If there is no stored data, the axis will appear, but the chart will be blank. (See the following section 

 

for information on Chart Navigation.)

Modes use

   

and 

 

 

Navigation of Charts

The Kestrel 4200 is capable of storing up to 1600 data points for each measurement. To review the data, 
press the 

 button while viewing a chart. A cursor will appear on the most recent data point. Press the   

and 

 buttons to scroll through the data points. The date and time at which the data was stored will be 

displayed at the bottom of the screen, and the data value will be displayed at the top of the screen.  Hold 
down the   or 

 button to scroll quickly through the data points.

Press the 

 or 

 button to review the data for the other measurements. Please note that the cursor will 

remain at the same date and time.  If new data is stored while viewing chart data, the entire chart will shift 
left with the new data point charted on the right.  The cursor will not shift with the chart.

Press the 

 button to return to the Chart Mode.

Value

Date & Time

Chart

Cursor

5

5

GETTING STARTED

Pouch and Lanyards

Wrist and neck lanyards and a small pouch have been provided. To install the lanyard, 
feed the thin end of the lanyard around the metal post on the battery door (as shown 
in diagram). Feed the thick end of the lanyard through the loop on the thin end. Using 
tweezers can help.

Battery Installation

Use only AAA batteries. Install batteries as indicated on the battery door. After installing 
the batteries, the Kestrel 4200 will automatically start in the Date and Time Setting mode. (See Date and 
Time Setup below.) Custom settings and chart data will be saved during a battery change; only the date/
time and MMA values will be lost. 

Turning the Kestrel Meter ON and OFF

To turn the Kestrel Meter ON, press 

 the button. To turn the Kestrel Meter OFF, hold the 

 button for two 

seconds. Or, press the 

 button, then press the 

 button with the word OFF highlighted. (Note: your unit 

will continue to automatically store data when the power is turned off .) When fi rst turned on, the Kestrel 
Meter will display a splash screen displaying the model number, the battery indicator, and the code version. 
This battery indicator will indicate the percentage of battery life remaining, which is helpful in preventing 
unexpected dead batteries.

Date and Time Setup

The fi rst time that you turn on your Kestrel Meter, as well as after a battery change, you 
will need to set the date and time. The Introduction Screen will appear for 3 seconds, 
followed by the Date/Time Setup Screen. Press the 

 and 

 buttons to scroll through 

the settings. Press the   and   buttons to scroll through the setting options. After 

8

Kestrel

®

 4200 Pocket Air Flow

®

 Tracker

SPECIAL FUNCTIONS

User Screens

 

The Kestrel Meter has three User Screens that can be customized to display three  

 

current measurements simultaneously. These screens can also be turned off . (See the  

 

Main Menu section for setup instructions.) 

 

Max/Avg for Air Flow, Air Velocity & Wind Chill

 

The Max/Avg values for Air Flow, Velocity and Wind Chill are measured independently 

from the stored and charted data. This allows the user to start and stop the averaging period in the most 
appropriate manner for their application. Averaging on all velocity-related values (air fl ow, air velocity and 
wind chill) will be started and stopped together.

While viewing the Min/Max/Avg screen for any of these measurements, hold the unit into the wind, and 
press the 

 button when the screen displays “--average” to begin collecting data for all measurements, and 

again when the screen displays “--stop” to stop collecting data and hold the values on the display.  Press 
the 

 button when the screen displays “--clear” to clear the data. This routine will work simultaneously 

for all measurements, regardless of which one is displayed while the routine is run.  The Max/Avg for these 
velocity values will not aff ect any other Min/Max/Avg or stored data.

Manual Data Storage

To manually store data, press the 

 button. One of the following will appear: Data Stored (data has been 

captured and will appear on chart), Full (Overwrite is off  and data log is full), or Off  (Manual Store button 
has been disabled). (See the Main Setup Menu section for more information on memory.)

6

Kestrel

®

 4200 Pocket Air Flow

®

 Tracker

entering the date and time, press the 

 button to exit the Date/Time Setup. Then press the 

 button 

again to exit the Main Setup Menu.

NAVIGATION

Measurements use 

 and 

 

   Air Flow

     Air Velocity

       Temperature

    Wind Chill

     Humidity

HUM

RATIO

  Humidity Ratio

       Heat Index 

     Dew Point

     Wet Bulb

   Barometric Pressure

  Altitude

   Density Altitude

The Kestrel 4200 is set up to display 12 Measurements (some are 
calculations) in 3 Modes. 

The Measurements are listed here with their corresponding screen 
icon. In addition to these Measurements and Modes, there are also 3 
User Screens, which simultaneously show 3 current measurements, 
and the Date & Time Screen, which gives the current date and 
time. Use the 

 and 

 buttons to scroll through the various 

Measurements, followed by the 3 User Screens and the Date/Time 
Screen. Any of these screens can be turned off  so that you can 
customize your Kestrel Meter to show the screens that your application 
requires. (See the Measurements section in the Main Menu.)

The Modes are displayed below. Use the   and 

 buttons to scroll 

through the various Modes. From any mode, you may still scroll to a 
diff erent Measurement by pressing the 

 and 

 buttons.

 

Current

 - Displays the instantaneous reading.

   

Min/Max/Avg

 - Displays the Minimum/Maximum/Average readings 

from stored data. If there is no stored data, the values will be 
displayed as --.-. 

HI

DP

WB

D

Summary of Contents for 4200

Page 1: ... 25 CUSTOMER SERVICE 27 Congratulations on the purchase of your Kestrel 4200 Pocket Air Flow Tracker The Kestrel 4200 is our newest and most comprehensive HVAC specific instrument It not only measures EVERY major environmental condition easily accurately and right in the palm of your hand but now also automatically calculates Volume Air Flow CFM and Humidity Ratio grains While the Kestrel 4200 is ...

Page 2: ...r 8 Kestrel 4200 Pocket Air Flow Tracker SPECIAL FUNCTIONS User Screens The Kestrel Meter has three User Screens that can be customized to display three current measurements simultaneously These screens can also be turned off See the Main Menu section for setup instructions Max Avg for Air Flow Air Velocity Wind Chill The Max Avg values for Air Flow Velocity and Wind Chill are measured independent...

Page 3: ...t Air Flow screen simply press the 12 Kestrel 4200 Pocket Air Flow Tracker Starting with a known altitude for your location You can obtain your altitude from a topographical map or local landmark Google Earth is an excellent free program that provides the exact altitude for any given address www earth google com Set this value as your reference altitude on the BARO screen to determine your baromet...

Page 4: ...DENSITY ALTITUDE screen is calculated from the absolute values of station pressure relative humidity and temperature and is not affected by the reference values entered in the BARO and ALTITUDE screens MAIN SETUP MENU You can customize your Kestrel Meter in multiple ways Press the button to access the Main Setup Menu Press the button to select the highlighted setting The Main Setup Menu contains O...

Page 5: ...ocket Air Flow Tracker APPLICATION EXAMPLES This section provides examples of applications where a Kestrel Meter might be used and the appropriate memory settings HVAC Environmental Monitoring Auto Store On Store Rate 5 min Overwrite On Man Store Off These settings will record conditions every five minutes for a total storage of almost 7 days You can monitor the conditions in a laboratory or manuf...

Page 6: ...s available for a more in depth definition On the internet visit www usatoday com or www noaa gov Or locate the USA Today publication The Weather Book Please note that any words in a definition printed in italics are themselves defined in this glossary 24 Kestrel 4200 Pocket Air Flow Tracker Some exercise physiology guides use wet bulb temperature rather than heat index as a measure of the safety ...

Page 7: ...ill be but for the most accurate readings at your particular location the Kestrel Meter is better CUSTOMER SERVICE Kestrel Pocket Weather Meters Warranty NK does not believe in disposable electronics We know that Kestrel Meters don t typically lead pampered lives and we design them for years of performance in tough conditions Every Kestrel Meter is designed and manufactured at NK s facility in Boo...

Page 8: ...s within 30 days of purchase and we will test and recalibrate all values at no charge Beyond 30 days we offer reasonably priced tests calibration services and N I S T certified calibrations as well as Kestrel Meter tune ups All of our measurements are traceable to the National Institute of Standards and Technology ensuring the highest level of accuracy Our primary Calibration Standards are sent fo...