20
At this point, the amplifier should appear as shown in Figure 3.15.
Figure 3.15: Amplifier after T/R Relay Removal
Two coaxial cables emanate from the QSK T/R Relay PCB. The shorter coaxial cable
provides RF drive to the amplifier and must be connected to the amplifier’s tuned input
network. Refer to Figure 3.16 on page 21:
•
Solder the shorter coaxial cable’s braid to the ground post near the tuned input con-
nector.
•
Attach the coaxial cable center conductor to the tuned input post (Do NOT melt the
nylon insulation).
The completed tuned input connections should appear as shown in Figure 3.16.
www.KesslerEngineeringLLC.com
Summary of Contents for TL-922 Revival (tm)
Page 13: ...6 Figure 3 1 TL 922 Revival tm Upgrade Kit Contents www KesslerEngineeringLLC com...
Page 18: ...11 Figure 3 4 LED Circuit Board Correctly Installed www KesslerEngineeringLLC com...
Page 30: ...23 Figure 3 19 QSK PCB to QRO Output Connections www KesslerEngineeringLLC com...
Page 34: ...27 Figure 3 23 Electronic Bias PCB Installed www KesslerEngineeringLLC com...
Page 47: ...40 Figure 3 30 Step Start PCB www KesslerEngineeringLLC com...
Page 49: ...42 Figure 3 33 LED Schematic Diagram Figure 3 34 LED PCB www KesslerEngineeringLLC com...
Page 50: ...43 Figure 3 35 Electronic Bias Schematic Diagram www KesslerEngineeringLLC com...
Page 51: ...44 Figure 3 36 Electronic Bias PCB www KesslerEngineeringLLC com...
Page 54: ...47 User Notes www KesslerEngineeringLLC com...
Page 55: ...48 5 1 User Notes Continued www KesslerEngineeringLLC com...
Page 56: ...49 5 2 User Notes Continued www KesslerEngineeringLLC com...
Page 57: ...50 5 3 User Notes Continued www KesslerEngineeringLLC com...