34 / 180
General information about these instructions
016-023
1.1
Product description, general
Ill. [1]
The backwater valves Staufix (referred to as backwater valve below) have been designed for
various applications:
Application / function
↓ Variant
Type in accordance
with EN 13564
Emergency closure
Control unit
Backwater valve Staufix Control
..type 2*
x
x
Backwater valve Staufix
..type 2*
x
(x)
Backwater valve Staufix**
..type 1*
x
(x)
Clean out (inspection)
- -
- -
- -
* DIN EN 13564
** can be retrofitted into a backwater valve type 2
x Standard (x) optional, retrofittable
1
The products are designed for installation in the concrete slab <1> or in exposed pipes <2> for
wastewater without sewage.
With the product variant "Staufix Control"
2
an optical and acoustic alarm message is given if
backwater occurs. At the same time, the alarm can be received wirelessly by a remote signal
receiver. With the radio receiver as a switched socket, any consumer (techn. data see product
data sheet) can be switched off. A maximum of 3 switched sockets can be integrated.
1) By replacing the cover (lockable cover with control unit)
2) Control unit is installed