EN
4
Installation
4.1
Setting the system in place
The tank must be aligned vertically on a clean layer.
Alternatively, the system tank can also be fastened with
threaded rods (max. M10) fed through the eyes in the
edge of the system tank.
The profile lip seal must be placed in the tank groove.
Determine the height to the planned floor level, checking
whether the installation of an additional extension sec-
tion is necessary. The upper section is height-adjustable.
However, the minimum insertion depth (47 mm) of the
upper section must be taken into account. The upper sec-
tion can be shortened accordingly if necessary.
Trial-fit upper section and cover plate.
The cover plate also provides protection during the con-
struction period.
To guarantee easier fitting of the upper section, grease
the profile lip seal sufficiently with fittings grease.
32 / 136
016-083