3
Technical data
Information / pump type
GTF 600
GTF 1250
Weight
6 kg
10 kg
Power P1 / P2
650W / 400 W
1.3 kW / 0.8 kW
Speed
2750 rpm
2700 rpm
Operating voltage
230 V; 50 Hz
230 V; 50 Hz
Nominal current (per pump)
2.9 A
5.4 A
Max. pumping capacity
12 m³/h
20 m³/h
Max. pumping height
8 m
10 m
Max. temperature
Pumped medium
35°C
35°C
Protection rating
IP68 (3m)
IP68 (3m)
Protection class
I
I
Operating mode
S1
S3 (50%)
Motor protection
integrated
integrated
Recommended fuse
(Mono)
Recommended fuse (Duo)
C16 A
C16 A
C16 A
C16 A
Residual current device (RCD)
30 mA
30 mA
Pumping capacity and height of the pumps
Fig. 1: Pumping capacity diagram
Tank
Data
Values
Weight
16 kg
Inlet [DN]
100 / 150
must be drilled on-site
Pressure connection [DN]
50 (d=63 mm) for PVC
Cable conduit
must be drilled on-site
must be drilled on-site
Ventilation
must be drilled on-site
Height
830 mm
Outside diameter
600 mm
Cover plate / version
walkonable up to 300 kg
Pumping volume
60 l
EN