41
3. Installation and Assembly
Installation dimensions of sensor
Freie Auf-
stellung
Artikelnummer
NS
Abstand Oberkante
unterer Finger zu
Unterkante Auslauf
(Wasserlinie)
Alarmschichtdicke
in cm
Voralarmschichtdicke
in cm bei 80%
max. Schlammschicht-
dicke in cm = 50% des
Schlammfangvolumen
DS
93002.01/DS, .02/DS, .31/DS, .32/DS
2
50 cm
14
11
22
93003.01/DS, .02/DS, .31/DS, .32/DS
3
50 cm
17
14
29
93004.01/DS, .02/DS, .31/DS, .32/DS
4
50 cm
16
14
30
93007.01/DS, .02/DS, .31/DS, .32/DS
7
50 cm
21
17
35
93010.01/DS, .02/DS, .31/DS, .32/DS
10
50 cm
21
17
38
DSP
93002.01/DSP, .02/DSP
2
50 cm
14
11
22
93003.01/DSP, .02/DSP
3
50 cm
17
14
29
93004.01/DSP, .02/DSP
4
50 cm
17
14
30
93007.01/DSP, .02/DSP
7
50 cm
21
17
35
93010.01/DSP, .02/DSP
10
50 cm
21
17
38
MS
93002.01/MS, .02/MS
2
50 cm
14
11
22
93003.01/MS, .02/MS
3
50 cm
17
14
29
93004.01/MS, .02/MS
4
50 cm
17
14
30
93007.01/MS, .02/MS
7
50 cm
21
17
35
93010.01/MS, .02/MS
10
50 cm
21
17
38
PVS
93002.01/PVS, .02/PVS
2
50 cm
14
11
22
93003.01/PVS, .02/PVS
3
50 cm
17
14
29
93004.01/PVS, .02/PVS
4
50 cm
17
14
30
93007.01/PVS, .02/PVS
7
50 cm
21
17
35
93010.01/PVS, .02/PVS
10
50 cm
21
17
38
free
standing
Article No.
Distance between the
upper edge of the
lower “finger” and the
lower edge of the out-
let (water line)
Alarm level layer
thickness in cm
Recommended pre-
liminary alarm level in
cm (= 2/3 of the max.
storage volume)
max. sludge layer in cm
( = 50% of sludgetrap
volume)
Summary of Contents for 917824
Page 32: ......
Page 64: ...64 ...
Page 96: ...96 ...
Page 128: ...128 ...
Page 160: ...168 ...
Page 193: ...193 NOTIZEN ...
Page 194: ...194 NOTIZEN ...
Page 195: ...195 ...