59
SPECIFICATIONS
SPECIFICATIONS KERO
MODELE
SRE 3002/ FR 32
SRE 4602 / FR 46
Type
Gasification at direct injection
Ignition
Coil high voltage
Fuel max
Liquid combustible for mobile heater
Fuel consumption
MAX
250
383
(g/h)
Average
158
236
MIN
65
90
Fuel consumption
MAX
0.32 l/h
0.49 l/h
(l/h
Average
0.20 l/h
0.28 l/h
MIN
0.08 l/h
0.11 l/h
Nominal output
MAX
3000
4600
(Watt)
Average
1890
2840
MIN
775
1080
Fuel tank capacity (L)
4.0 L
7.1 L
Continuous
combustion
capacity
MAX
49.4 h
64.5 h
MIN
12.5 h
14.5 h
Suitable room size
in m³ MAX
120
184
Unit overall dimensions (HxWxD) mm
415x400x300
455x500x310
Weight kg
10.8 kg
13.6 kg
Voltage and frequency
230V Mono phase, 50HZ
Rated power consumption(W)
30 W
35 W
Fuse
Tube type 6.3 A
Safety devices
Auto Shut-off Device, Anti-Overheat Device,
CO2
Detector, Presence of tank detector
, Power Failure
Safety Device, Combustion Stabilizer, Safety Ignition
System, Combustion Control System