4.3  Warranty 

Warranty claims shall be voided in case  

 

  Our conditions in the operation manual are ignored 

  The appliance is used outside the described uses 

  The appliance is modified or opened 

  Mechanical damage and damage caused by media, liquids  

  Natural wear and tear 

  The appliance is improperly set up or incorrectly electrically connected 

  The measuring system is overloaded 

4.4  Monitoring of Test Resources 

In the framework of quality assurance the measuring-related properties of the 
balance and, if applicable, the testing weight, must be checked regularly. The 
responsible user must define a suitable interval as well as type and scope of this test. 
Information is available on KERN’s home page (www.kern-sohn.com) with regard to 
the monitoring of balance test substances and the test weights required for this. In 
KERN’s accredited DKD calibration laboratory test weights and balances may be 
calibrated (return to the national standard) fast and at moderate cost. 

Summary of Contents for UOB 1.5T0.5

Page 1: ...n GmbH Ziegelei 1 D 72336 Balingen email info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Pallet scales KERN UOB Version 1 3 05 2009 GB UOB BA e 0913 ...

Page 2: ..._____________________ 8 6 2 Packaging _______________________________________________________ 8 7 Unpacking Setup and Commissioning _____________________________ 9 7 1 Installation Site Location of Use ____________________________________ 9 7 2 Unpacking ______________________________________________________ 10 7 2 1 Scope of delivery _____________________________________________________ 10 7 3 Pl...

Page 3: ...g function ____________________________ 19 8 8 Weight units ____________________________________________________ 19 9 Service maintenance disposal___________________________________ 20 9 1 Cleaning _______________________________________________________ 20 9 2 Service maintenance_____________________________________________ 20 9 3 Disposal________________________________________________________ 20...

Page 4: ...500 kg Reproducibility 300 g 0 5 kg Linearity 400 g 1 kg Recommended adjustment weight not added class 500 kg M2 1000 kg M2 Stabilization time typical 3 sec Operating temperature 5 C 35 C Humidity of air max 95 not condensing Terminal B x D x H mm 210 x 110 x 45 Weighing plate mm 1255 x 820 x 90 5 Weight kg net 36 7 ...

Page 5: ...as normas siguientes F Déclaration de conformité Nous déclarons avec cela responsabilité que le produit auquel se rapporte la présente déclaration est conforme aux normes citées ci après I Dichiarazione di conformitá Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate NL Conformiteit verklaring Wij verklaren hiermede dat het p...

Page 6: ...ed to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the balance Example Slowly draining fluids from a container on the balance Do not leave permanent load on the balance This may damage the measuring system Impacts and overloading exceeding the stated maximum load max of the balance minus a possibly existing tare load must be strictly a...

Page 7: ...ded 4 4 Monitoring of Test Resources In the framework of quality assurance the measuring related properties of the balance and if applicable the testing weight must be checked regularly The responsible user must define a suitable interval as well as type and scope of this test Information is available on KERN s home page www kern sohn com with regard to the monitoring of balance test substances an...

Page 8: ...liance may only be operated and maintained by trained personnel 6 Transportation Storage 6 1 Testing upon acceptance When receiving the appliance please check packaging immediately and the appliance itself when unpacking for possible visible damage 6 2 Packaging Keep all parts of the original packaging in case you need to return the appliance Only use original packaging for returning Before sendin...

Page 9: ...igh humidity vapors and dust Do not expose the device to extreme dampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acclimatize the disconnected appliance for ca 2 hours at room temperature Avoid static charging of the material to be weighed weighing co...

Page 10: ...sories KERN UOB Platform varnished metal and display equipment 4 x adjustable feet Mains power supply Wall fixture with fixing screws Operating Manual 7 3 Placing Ö Place pallet scales on the installation site To transport the pallet scales Lift off by the handle and move it on the conveyor rollers Ö Avoid any pressure on the load cells Ö Put the cable to the weighing terminal in a manner that it ...

Page 11: ...y KERN 7 5 Battery operation Ö Remove battery cover from under the display unit Connect 6 x 1 5V mignon cells Reinsert the battery cover In order to save the battery the balance switches automatically off after 3 minutes without weighing If the batteries are run down LO appears in the display Ö Press key and replace the batteries immediately If the balance is not used for a longer time take out th...

Page 12: ...d in compliance with the underlying physical weighing principle to the existing acceleration due to gravity at its place of location only if the balance has not already been adjusted to the location in the factory This adjustment process must be carried out during the initial start up after change in location and variation of surrounding temperature To receive accurate measuring values it is also ...

Page 13: ...until SETUP is displayed followed by UNIT SETUP Ø UNKT Ö Press the button as often as required until CAL ib is displayed CAL K B Ö Press button CAL U Ö Press button The appeared triangle W must be located in the upper left part of the display If this is this not the case press the button Ö Press the button repeatedly until CAL 0 is displayed CAL U Ø CAL O Ö Press button in the display appears a nu...

Page 14: ...value u000 Example Ö Confirm with UNIT button 0 Ö Place the adjustment weight carefully in the centre of the weighing plate and a numerical value will appear in the display Ö Press button The adjustment process is started 82077 Example The balance will automatically return to Weighing mode upon successful completion of the adjustment and will display the weight of the adjustment weight Take away a...

Page 15: ...ould the balance not display exactly zero despite an empty scale pan press the 0 button Your balance will be set to zero after a short standby time 2 ο Stability display If the display shows the stability display ο the balance is in a stable status The ο indication disappears if the condition is unstable 3 Hold S Hold animal weighing function active ...

Page 16: ...ghing function Tare balance 8 3 Operation limits The pallet scales is designed for an even distributed load Avoid falling load shock loads and impacts from the side The forks of the fork lift truck may not touch the pallet or the balance during weighing process Do not move the balance at any moment when it is loaded ...

Page 17: ... it is removed or newly placed 8 5 Weighing Operation Display Ö Use the button to switch the balance on The balance shows for approx 3 seconds 88888 and then P1 1 in the display and then goes to 0 Now it is ready for operation 88888 Ø Ø 0 0 Should the display flash or not be on 0 press the TARE button Ö Only now place goods onto weighing plate The result is displayed 30 0 Example If the material t...

Page 18: ... 0 The weight of the container is now internally saved 0 0 If one after finishing the weighing process presses again the TARE button 0 appears anew in the display The taring process can be repeated any number of times e g when adding several components for a mixture adding The limit is reached when the whole weighing range is exhausted After removing the taring container the total weight is displa...

Page 19: ...d wait for the 0 display 0 0 Ö Press button Hold will appear in the display and the S under HOLD flashes Ö Put goods to be weighed animal on the weighing plate As long as the triangle flashes the balance takes up several measured values and displays then the calculated mean value 30 0 Example Press the button repeatedly to reset the balance to normal Weighing mode Press the button once more to rep...

Page 20: ...and wipe with a dry soft cloth Loose residue sample powder can be removed carefully with a brush or manual vacuum cleaner Spilled weighing goods must be removed immediately 9 2 Service maintenance The appliance may only be opened by trained service technicians who are authorized by KERN Before opening disconnect from power supply 9 3 Disposal Disposal of packaging and appliance must be carried out...

Page 21: ...ayed weight is permanently changing Draught air movement Table floor vibrations The weighing plate is in contact with foreign matter Electromagnetic fields static charging choose different location switch off interfering device if possible The weighing value is obviously The display of the balance is not at zero wrong Adjustment is no longer correct Great fluctuations in temperature Electromagneti...