7.1.5 Unit 

change 

Switch the balance on by pressing the 

 key, then wait for the 

“0”

 indication.

 

The units set in the balance can be selected between the different units, by pressing 

the 

 key 

 

 

Display 
 

Conversion factor 
1 g = 

Gramm * 

1. 

Tael Taiwan 

tlt 

0.02667 

Tola tol 

0.08573 

* Factory setting 
 

 

8  Maintenance, upkeep, disposal 

8.1 Cleaning 

Please disconnect the device from the operating voltage before cleaning.  

Only use a cloth dampened with mild suds and not aggressive cleaning agents (sol-
vents or similar). Please ensure that fluids are not able to get into the device and rub 
off using a clean, soft cloth.   
Loose sample residue/powder can be removed carefully using a brush or hand vac-
uum cleaner. 

Remove any spilt material to be weighed immediately. 

 

 

8.2 Maintenance, 

upkeep 

The device may only be opened by trained service engineers authorised by KERN.   

8.3 Disposal 

The operating company shall dispose of the packaging and the device in compliance 
with the valid national or regional law of the operating location. 

Summary of Contents for TEB

Page 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instruction Pocket balance KERN TEB Version 1 0 10 2005 GB TE...

Page 2: ...ng 5 5 Transport and storage 5 5 1 Acceptance check 5 5 2 Packaging 5 6 Unpacking installation and commissioning 6 6 1 Place of installation place of use 6 6 2 Unpacking 7 6 2 1 Installation 7 6 2 2 L...

Page 3: ...sion 89 336 EEC Compatible norms are in particular Standards for electronic scale EN 61000 6 3 2001 EN 61000 6 1 2001 If a change is made to the above mentioned appliances without consulting KERN this...

Page 4: ...n the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the balance Example Slowly drain i...

Page 5: ...om with regard to the monitoring of balance test substances and the test weights required for this Test weights and balances can be adjusted quickly and at a reasonable price in KERN s accredited DKD...

Page 6: ...ts due to open windows and doors Avoid jarring during weighing Protect the balance against high humidity vapours and dust Do not expose the device to extreme dampness for longer periods of time In adm...

Page 7: ...easured values after switching on The accuracy of the balance depends on the local acceleration of the fall Please be sure to observe the information in the chapter on adjusting 6 5 Adjustment As the...

Page 8: ...late F will appear somewhat later and then turn off In case of an adjusting error or a wrong adjusting weight E appears in the display 7 Operation 7 1 Overview of display Units on display 7 1 1 Weighi...

Page 9: ...on the weighing pan successively the balance will show any devia tion from the rated weight in and According to the same procedure packages with the same weight related to a rated weight can be produc...

Page 10: ...aning Only use a cloth dampened with mild suds and not aggressive cleaning agents sol vents or similar Please ensure that fluids are not able to get into the device and rub off using a clean soft clot...

Page 11: ...tinu ally Draught air movement Table floor vibrations The weighing plate is in contact with for eign matter Electromagnetic fields static charging choose different location switch off inter fering dev...

Reviews: