background image

7  Operation 

7.1  Display control panel 

 

 

Keyboard 

 

 

 
ON / OFF 

 

 

Print weighing result 

in MODE:  No / descending

 

 

in % and counting mode:

 

 

Form reference  

in MODE:  Yes / ascending

 

 
MODE configuration 

(see mode structure diagram page 2)

 

 

Formula weighing 

in MODE:  to left 
Change g-pieces

 

 
Unit changeover 

in MODE:  to right

 

 
Tare 

in MODE:  back in weighing operation

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 

 

Display-Symbol Meaning 

 

==

OVERLOAD

== 

Overload: Weighing range has been exceeded 
 

= ============ 

Underload: Weighing range has been fallen short of 
 

           

<<

            . 

In counting and % mode: part too light 
 

 

…

                       

 

Automatic tare active 

 PTA                   

             

Preselect tare        Tare pre-selection active  

 D                        

             

Difference in %  during percentage weighing  

 Net                     

             

Net weight of the components during formula preparation  

 SUM                  

             

Gross weight of several components during formula prepa-
ration 

  

Æ

                      .       

Balance is in counting mode and currently displaying the 
weight value of the counting amount 

 

 

 

572/573/KB/DS/FKB/FCB/PCB-BA-e-0853 

15

Summary of Contents for PCB 10K0.05B

Page 1: ...info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instruction Precision compact balances and platform scales KERN 572 573 KB DS FKB FCB PCB Version 5...

Page 2: ...tion ______________________________________ 12 4 1 Observe the information in the operating instructions ______________________ 12 4 2 Staff training __________________________________________________...

Page 3: ...________________________________________________________ 18 7 2 12 Preselect Unit ___________________________________________________________ 18 7 2 13 Display background illumination ________________...

Page 4: ...1 MODE MENUE 572 573 KB DS FKB FCB PCB BA e 0853 4...

Page 5: ...ousing B x D x H mm 180 x 310 x 90 Vibration filter yes Weighing plate mm 106 106 150 150 Units see menu Weight kg net 2 3 2 3 2 3 2 3 2 3 Data interface yes RS232 KERN 572 37 572 45 572 49 572 57 Rea...

Page 6: ...Linearity 0 2 g Smallest piece weight 0 3 g Recommended adjusting weight F2 not supplied 5 kg Verification value 1 g Humidity of air max 80 rel not condensing Stabilization time typical 2 sec Allowabl...

Page 7: ...H mm 165 x 230 x 85 Weighing plate mm 81 81 130 x 130 150 x 170 Units see menu Vibration filter yes Weight kg net 1 1 1 1 1 2 1 2 1 6 Data interface yes RS232 2 4 KERN FKB KERN FKB 8k0 05 FKB 16k0 1 F...

Page 8: ...5x70 Weighing plate stainless steel 228x228 315x305 228x228 315x305 315x305 Units see menu Vibration filter yes Weight kg net 5 5 7 5 5 5 7 5 7 5 Data interface yes RS232 KERN DS 36K0 2 DS 36K0 2L DS...

Page 9: ...ty 0 003 g 0 003 g 0 03 g 0 03 g 0 15 g Smallest piece weight 0 001 g 0 001 g 0 01 g 0 01 g 0 05 g Recomm adjusting weight F1 not sup plied 200 g 200 g 2000 g 2000 g 10 kg Humidity of air max 80 rel n...

Page 10: ...weighed It is intended to be used as a non automatic balance i e the material to be weighed is manually and carefully placed in the centre of the weighing plate The weighing value can be read off afte...

Page 11: ...or electric installation overloading of the measuring equipment 3 4 Monitoring the test substances The metrology features of the balance and any possible available adjusting weight must be checked at...

Page 12: ...ing plate power unit etc to prevent slipping and damage 6 Unpacking installation and commissioning 6 1 Place of installation place of use The balance is constructed in such a way that reliable weighin...

Page 13: ...values after switching on The accuracy of the balance depends on the local acceleration of the fall Please be sure to observe the information in the chapter on adjusting 6 6 Adjustment As the acceler...

Page 14: ...be secured by a verification mark against access 6 8 Verification General According to the EU guideline 90 384 EEC balances must be verified officially if they are to be used as fol lows legally regu...

Page 15: ...Display Symbol Meaning OVERLOAD Overload Weighing range has been exceeded Underload Weighing range has been fallen short of In counting and mode part too light Automatic tare active PTA Preselect tar...

Page 16: ...7 2 Operation 7 2 1 Weighing with Tare 7 2 2 Count Selection Preference Piece 7 2 3 Percent 7 2 4 Formula Weighing 7 2 5 Tolerance Weighing 572 573 KB DS FKB FCB PCB BA e 0853 16...

Page 17: ...572 573 KB DS FKB FCB PCB BA e 0853 17 572 573 KB DS FKB FCB PCB BA e 0853 17...

Page 18: ...7 2 6 Adjust 7 2 7 Preselect Tare 7 2 8 Auto Tare 7 2 9 Speed 7 2 10 Auto Off 7 2 11 Variable Factor 7 2 12 Preselect Unit 572 573 KB DS FKB FCB PCB BA e 0853 18...

Page 19: ...572 573 KB DS FKB FCB PCB BA e 0853 19...

Page 20: ...top bits no parity bit Baud rate adjustable to 2400 4800 and 9600 baud default 19200 baud Sup D 9 pol is necessary When working with an interface correct operation is secured only if the corresponding...

Page 21: ...there it can be selected or deselected When AUTOPRINT PC is active the actual weighing values will be sent continuously via the RS 232 interface Data output by transfer of remote controls The followin...

Page 22: ...size or shape cannot be put on the scale can be weighed by means of underfloor weighing Proceed as follows Switch off the balance Turn the balance over without loading the balance plate Open the cove...

Page 23: ...ched off for a short time following an interruption in the programme sequence and disconnected from the mains supply It is then necessary to repeat the weighing process from the be ginning Help Interr...

Page 24: ...n est de acuerdo con las normas siguientes F D claration de conformit Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci...

Page 25: ...e se refiere esta declaraci n est de acuerdo con las normas siguientes F D claration de conformit Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est c...

Page 26: ...ion de conformit Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s Cette d claration est valide seulement avec un...

Reviews: