OZL-45-BA-e-1510

 

Before use 

1.1  General notes 

You must open the packaging carefully, to make sure that none of the accessories in 
the packaging fall on the floor and get broken. 

In  general,  microscopes  should  always  be  handled  carefully  because  they  are 
sensitive  precision  instruments.  When  using  or  transporting  the  microscope  it  is 
particularly  important  to  avoid  abrupt  movements,  as  this  may  damage  the  optical 
components. 

You  should  also  avoid  getting  dirt  or  finger  prints  on  the  lens  surface,  because  in 
most cases this will reduce image clarity. 

To maintain the performance of the microscope, it must never be disassembled. So 
components  such  as  lenses  and  other  optical  elements  should  be  left  as  they  were 
before use. Also the electrical parts in the base of the device must not be tampered 
with, as in this area there is an additional risk of triggering an electric shock. 

1.2  Notes on the electrical system

 

(OZL 451) 

Before connecting to a mains power supply, you must make sure that you are using 
the  correct  input  voltage.  The  information  to  select  the  correct  power  supply  is 
located  on  the  device,  on  the  rear  of  the  stand  base.  You  must  comply  with  this 
information.  If  you  do  not  comply  with  these  specifications,  then  fires  or  other 
damage to the device could occur. 

The  lighting  unit  must  also  be  switched  off  before  the  mains  cable  is  connected.  In 
this way you will avoid triggering an electric shock. 

If you are using an extension cable, then the mains cable you use must be earthed. 

If  the  original  fuse  should  blow,  it  must  only  be  replaced  by  an  appropriate  fuse. 
Suitable replacement fuses are included with the delivery. 

When carrying out any procedures whereby you come into contact with the electrical 
system of the device, such as, for example, changing the bulb or fuse, only carry out 
these procedures when the power is disconnected. 

Under no circumstances should you touch the integrated halogen bulbs or housings 
either during operation or directly after use. These bulbs produce significant heat and 
therefore there is a risk that the user could be severely burnt. So before handling the 
bulbs, you must check that they have cooled down. 

Summary of Contents for OZL-45

Page 1: ...ohn GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Stereo zoom microscope KERN OZL 45 OZL 451 OZL 4...

Page 2: ......

Page 3: ...5 Operation and functionality 10 5 1 Getting started 10 5 2 Adjusting the interpupillary distance 10 5 3 Adjusting the magnification 10 5 4 Dioptre adjustment and focussing 11 5 5 Adjusting the stand...

Page 4: ...make sure that you are using the correct input voltage The information to select the correct power supply is located on the device on the rear of the stand base You must comply with this information I...

Page 5: ...older must not be rotated back too far If you do this there is a risk that the microscope could tip over When the microscope is not being used you should fit the objective cap and cover the microscope...

Page 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Page 7: ...OZL 45 BA e 1510 6 2 Nomenclature Using the OZL 451 as an example with lighting...

Page 8: ...55 75 mm Dioptre adjustment On both sides Packaging dimensions WxDxH 345x320x470 mm Standard configuration Model KERN Tube Eyepiece Field of view mm Objective Zoom Stand Illumination OZL 451 Binocula...

Page 9: ...ighting control for example we recommend that you position the head with the tube connectors centrally to the front Ideally the holder and head are then parallel on the central axis of the stand base...

Page 10: ...9 OZL 45 BA e 1510 Assembled stereo zoom microscope OZL 453...

Page 11: ...nterpupillary distances So each time a different person uses the microscope the gap between the two eyepieces must be re adjusted While you are looking through the eyepieces use one hand to hold the r...

Page 12: ...ugh the right eyepiece with the right eye and bring the object into focus by using the focus control dials 5 Now set the largest possible zoom factor 6 Once again still only looking through the right...

Page 13: ...could occur if the objective lens and the object being observed should collide Height adjustment Fixing the microscope holder With a stereo microscope on a pillar stand the microscope head can be hei...

Page 14: ...ied by the glasses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved W...

Page 15: ...tandard version the lighting is not suitable for the application then it often makes sense to fit an external lighting unit to overcome this problem The lighting units which are suitable for devices o...

Page 16: ...irst remove the holder and head of the microscope from the pillar In this way you can easily rotate the stand and replace the bulb To change the halogen bulb of a reflected light unit you must first u...

Page 17: ...5x 37 5x 255x Field of view mm 15 8 2 4 31 5 4 8 10 5 1 6 7 9 1 2 Working distance 113 mm 220 mm 50 mm 35 mm 7 Features Model outfit Kern model Order number OZL 451 OZL 453 Eyepieces HWF 5x 23 2 mm O...

Page 18: ...sufficient The wrong bulb has been used The input voltage is too low Optical unit Problem Possible causes You can see two images The interpupillary distance is not set correctly The magnifications of...

Page 19: ...materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Reviews: