background image

 

MBD-BA-e-1710 

 

 

 

3  Basic guidelines (general information) 

3.1  Proper use 

 
The scales are used to determine the weight of babies in a lying position; they are 
intended for private use. Using the scales in medicine is not allowed.  
In order to weigh the baby, put it on the weighing pan. The weight value can be read 
out once it is stabilised. 
An authorised person must check for proper condition of the scales prior to each use. 
 
 

Additional information on the baby scales: 

 
Baby scales are intended for the weighing of children in a lying position. If the child is 
to be weighed in a sitting position, place it in the centre of the weighing pan.  
 

You must continuously observe the baby placed on the weighing pan to 
avoid falling. Proceed according to the guideline placed on the weighing 
pan!  

 

                 

 

 
 

3.2  Improper use 

Do  not expose the weighing pan to a prolonged load. It may cause damage to the 
measuring mechanism. 
Always avoid impacts and overloads of the scales exceeding the specified maximum 
(

Max

) load by reducing the existing load with a tare. An impact or overload could re-

sult in damage to the scales. 
Never use the scales in potentially explosive areas. The serial product version is not 
explosion-proof.  
Do not introduce any structural modifications to the scales. It may cause incorrect 
weighing results, violation of technical safety conditions and may result in destruction 
of the scales. 
The scales must only be operated in accordance with the guidelines specified above. 
Other scopes/fields of use must be approved by KERN in writing. 
 

 

Summary of Contents for MBD 20K2

Page 1: ...n GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Baby scales KERN MBD Version 1 0 2017 08 GB MBD B...

Page 2: ...ptance 5 5 2 Packaging 5 6 Unpacking setup and start up 6 6 1 Site of installation location of use 6 6 2 Unpacking 6 6 2 1 Scales setup 6 6 2 2 Scope of delivery 6 6 3 Battery operation inserting and...

Page 3: ...e 10 min Operating temperature 10 C 40 C Auto Off 20 s Power supply battery operation 2 x 1 5 V type AAA operation time 20 h Air humidity max 80 non condensing Dimensions completely assembled W x D x...

Page 4: ...the baby placed on the weighing pan to avoid falling Proceed according to the guideline placed on the weighing pan 3 2 Improper use Do not expose the weighing pan to a prolonged load It may cause dam...

Page 5: ...site www kern sohn com The test weights and scales can be calibrated quickly and cheaply at KERN calibration labora tory accredited by DKD Deutsche Kalibrierdienst in reference to the national standar...

Page 6: ...bly warmer environment In this case acclimatize the device for approx 2 h at the ambient temperature Avoid static charge of the scales and persons to be weighed Avoid contact with water Major indicati...

Page 7: ...Initial start up To obtain accurate weighting results using the electronic balances the devices must reach an appropriate operating temperature see Chapter 1 Warm up time The scales must be turned on...

Page 8: ...hing can be tared by pressing the button during the subsequent weighing processes the scales will display the actual weight of the baby Place an object e g a towel or pad on the weighing pan Wait unti...

Page 9: ...The scales are provided with an integrated memory function that allows to memorise the weight values and display them when necessary Memorising the weight values Start the scales by pressing ON OFF a...

Page 10: ...calmly on the weighing pan Start the scales by pressing ON OFF and wait until the zero value appears Wait until the unstable symbol disappears Place the baby on the weighing pan Wait until the unstab...

Page 11: ...ressive cleaning agents solvents etc but clean the device us ing only a cloth moistened with a mild soap lye or a household cleaning agent En sure that no liquid penetrates into the device Wipe the de...

Page 12: ...ments of air Table floor vibration The weighing pan is in contact with solids or is in correctly installed Electromagnetic fields static charges choose an other location turn off the device causing th...