User Manual V3.1 

 

7

 

 

10

 

Technical characteristics

 

Characteristic 

Wirnet™ iFemtoCell

 

Enclosure material 

PC + ABS 

LED gasket material 

Elastomer compound based on styrene-butadiene-styrene (SBS) 

Dimensions L x H x P in mm: 

 

Without LoRa antenna 

 

With LoRa antenna

 

 
160 x 90 x 35 mm 
220 x 125 x 35 mm 

Weight in g (with AC power supply and LoRa RF antenna) 

280g 

Operating temperature range 

Enclosure: -20°C to +50°C 
Power supply: country dependent, please refer to power supply 
itself or contact your reseller 

Power supply output voltage 

12 VDC

 

Power consumption: 

 

CPU module (20% load), Ethernet link ON 

 

Wi-Fi (25%Tx,75%Rx) 

 

3G/4G USB dongle (HSPA, 25% Tx, 75% Rx) 

 

Radio in Rx mode (x8 demodulator on)

 

 
1.3W max 
0.5W max 
1W max 
1.6W max 

Ingress protection 

IP30 / EN 60529 

Humidity 

95% non-condensing 

Impact resistance 

IK07 

Flammability rating 

UL94-V0 

Connectors 

1 x SMA or RP-SMA (LoRa antenna) 
1 x jack connector (power supply) 
1 x USB 
1 x RJ45 

11

 

Declaration of conformity

 

11.1

 

Wirnet™ iFemtoCell 868MHz

 

The Wirne

t™ iFemtoCell 868 complies with

 

 

Directive 2014/53/EU relating to radio equipment (RED) 

 

Directive 2014/35/EU relating to electrical equipment designed for use within certain voltage limits (Low Voltage) 

 

Directive 2014/30/EU relating to Electromagnetic Compatibility 

 

Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (ROHS) 

 

Council Recommendation 1999/519/EC on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) 

 

The Wirnet™ iFemtoCell 868 is considered as a category 1.5 receiver

 according to the EN 300 220. 

The Wirnet™ iFemtoCell 868 has CE marking:

 

 

 

In Europe, the Wirnet™ iFemtoCell 868 station must comply with the ERC 70

-3  requirements regarding  duty cycle and maximum EIRP. They are 

summarized in the following table: 

 

ERC 70-03 Band 

Frequency (MHz) 

Power 

Duty cycle 

h1.3 

863-865 

14dBm ERP 

0,1% 

h1.3 

865-868 

14dBm ERP 

1% 

h1.4 

868-868,6 

14dBm ERP 

1% 

h1.5 

868,7-869,2 

14dBm ERP 

0,1% 

h1.6 

869,4-869,65 

27dBm ERP 

10% 

h1.7 

869,7-870 

14dBm ERP 

1% 

h2 

870-873 

14dBm ERP 

0,1% 

h2.1 

870-873 

14dBm ERP 

1% 

Annex2/c 

870-873 

27dBm ERP 

2,5% 

 

 

The power supply of the Wirnet™ iFemtoCell 868 must be a limited power source.

 

 
 

 

Summary of Contents for Wirnet iFemtoCell

Page 1: ...Vincent LOUVEAU 1 0 09 11 2018 11 3 Update 923MHz certifications Vincent LOUVEAU 1 1 18 02 2019 KerOS v4 0 modifications 6 4 Add Wi Fi direct connection 6 6 Update procedure and new configuration cap...

Page 2: ...ions technology 868MHz version RX 863 873MHz TX 863 873MHz according to HW capabilities 915MHz version 902 928 MHz ISM band hybrid mode according to HW capabilities 923MHz version RX 915 928 MHz TX 91...

Page 3: ...User manual this document 5 Markings 5 1 Markings on sticker Symbol Description Symbol Description Wirnet iFemtoCell Type of equipment QR code Power supply informations or other marking CE marking in...

Page 4: ...e possible regarding the technology used to access Internet Ethernet connection requiring an Ethernet access through a dedicated RJ45 cable Wi Fi connection requiring a Wi Fi access point 3G 4G connec...

Page 5: ...hnology Dipole VSWR 1 7 1 Max Gain 3dBi Polarization Vertical Whip material ABS Color White Connector WirnetTM iFemtoCell 915 RP SMA Size 135x20mm Weigh 15g Antenna operating temperature range 20 C to...

Page 6: ...act your reseller to know the LEDs behavior if the applicative software installed on the Wirnet iFemtoCell is not the one officially provided by KERLINK 6 6 Configuration Once the connection of your W...

Page 7: ...Check the position good connection of the RJ45 Ethernet connector Check that the RJ45 cable is not deteriorated In case of Wi Fi connection Check that the Wi Fi access point is within range of the Wi...

Page 8: ...68 complies with Directive 2014 53 EU relating to radio equipment RED Directive 2014 35 EU relating to electrical equipment designed for use within certain voltage limits Low Voltage Directive 2014 30...

Page 9: ...ers countries check the specific regulations regarding maximum EIRP and duty cycle allowed This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to p...

Page 10: ...tion of the use of certain hazardous substances in electrical and electronic equipment ROHS Council Recommendation 1999 519 EC on the limitation of exposure of the general public to electromagnetic fi...

Page 11: ...transmitter The power supply of the Wirnet iFemtoCell 923 must be a limited power source Depending on the countries check the specific regulations applying especially regarding frequency range maximum...

Reviews: