User Manual V3.1
7
10
Technical characteristics
Characteristic
Wirnet™ iFemtoCell
Enclosure material
PC + ABS
LED gasket material
Elastomer compound based on styrene-butadiene-styrene (SBS)
Dimensions L x H x P in mm:
•
Without LoRa antenna
•
With LoRa antenna
160 x 90 x 35 mm
220 x 125 x 35 mm
Weight in g (with AC power supply and LoRa RF antenna)
280g
Operating temperature range
Enclosure: -20°C to +50°C
Power supply: country dependent, please refer to power supply
itself or contact your reseller
Power supply output voltage
12 VDC
Power consumption:
•
CPU module (20% load), Ethernet link ON
•
Wi-Fi (25%Tx,75%Rx)
•
3G/4G USB dongle (HSPA, 25% Tx, 75% Rx)
•
Radio in Rx mode (x8 demodulator on)
1.3W max
0.5W max
1W max
1.6W max
Ingress protection
IP30 / EN 60529
Humidity
95% non-condensing
Impact resistance
IK07
Flammability rating
UL94-V0
Connectors
1 x SMA or RP-SMA (LoRa antenna)
1 x jack connector (power supply)
1 x USB
1 x RJ45
11
Declaration of conformity
11.1
Wirnet™ iFemtoCell 868MHz
The Wirne
t™ iFemtoCell 868 complies with
:
•
Directive 2014/53/EU relating to radio equipment (RED)
•
Directive 2014/35/EU relating to electrical equipment designed for use within certain voltage limits (Low Voltage)
•
Directive 2014/30/EU relating to Electromagnetic Compatibility
•
Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (ROHS)
•
Council Recommendation 1999/519/EC on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)
The Wirnet™ iFemtoCell 868 is considered as a category 1.5 receiver
according to the EN 300 220.
The Wirnet™ iFemtoCell 868 has CE marking:
In Europe, the Wirnet™ iFemtoCell 868 station must comply with the ERC 70
-3 requirements regarding duty cycle and maximum EIRP. They are
summarized in the following table:
ERC 70-03 Band
Frequency (MHz)
Power
Duty cycle
h1.3
863-865
14dBm ERP
0,1%
h1.3
865-868
14dBm ERP
1%
h1.4
868-868,6
14dBm ERP
1%
h1.5
868,7-869,2
14dBm ERP
0,1%
h1.6
869,4-869,65
27dBm ERP
10%
h1.7
869,7-870
14dBm ERP
1%
h2
870-873
14dBm ERP
0,1%
h2.1
870-873
14dBm ERP
1%
Annex2/c
870-873
27dBm ERP
2,5%
The power supply of the Wirnet™ iFemtoCell 868 must be a limited power source.