A specific crimping tool is required to perform the operation.
Figure 134 : Earthing of the outdoor Ethernet surge protection
Note 1:
the earthing cables are not provided by KERLINK
Note 2:
the earthing cables characteristics are detailed in §1.8.4.2.
4.6.1.6
Earthing of the outdoor PoE injector
On the outdoor PoE injector, the earthing connection is completed through a dedicated
earthing bolt and two nuts.
The earthing connection on the cable is completed through a ring terminal. A specific
crimping tool is required to perform the operation. The earthing cable must be crimped
inside this ring terminal.
The ring terminal is inserted between the two nuts as follows:
Figure 135 : Earthing of the outdoor PoE injector
Note 1:
the earthing cables are not provided by KERLINK
Note 2:
the earthing cables characteristics are detailed in §1.8.4.2.
Earthing screw