background image

EntraGuard

®

 Titanium Telephone Entry Controller

Quick Start Guide

Page 5 of 26

P/N: 01962-001 Rev. D

3.0

When Installing Controllers

DO

since this is a telephone entry system at least one phone line will be necessary, it is important to plan ahead to meet 
power and telephone requirements for your system (if using a modem, the host computer will need 1 phone line, plus 
one for each master controller in each network or each EntraGuard unit)

mount controllers in environmentally suitable areas - the EntraGuard Titanium unit is weather resistant, but care 
should be taken to avoid areas of weather/temperature/humidity extremes

mount the controller at least 3 feet away from the controller's power supply to prevent EMI radiated from the power 
supply from affecting the controller

use the enclosure as a mounting template to mark drilling holes for permanent mounting

note the locations of the knockouts in the enclosures and remove the appropriate knockout for the easiest cable 
routing into the controller

route all controllers in a network in a single, continuous daisy-chain (with the EntraGuard Titanium controller as the 
master)

route cables in accessible areas for ease of maintenance

connect all controllers to a quality earth ground

1

add transient suppression across electric devices attached to a controller output

use an isolation relay (P/N IRP-1) if attaching to a parking gate, a turnstile, or any application using a large electric 
motor

verify the controller's supply voltage is 12 VDC – long power line runs cause a drop in voltage at the end of the run

verify proper operation of the host computer's COM port or Ethernet/LAN WAN connection.

DO NOT

make modem phone line connections through PBX telephone switching systems - most modems are not compatible 
with PBX systems leading to disconnection problems with the modem

locate the EntraGuard Titanium controller near EMI sources - EMI sources can affect the performance of the 
controller

use switching power supplies - they are EMI sources

route network cables beside power cables - transients on the power cables may be picked-up by network and reader 
cables

stretch or over-tension cables

route over sharp objects

let the wires get tangled

route the EntraGuard Titanium controller as a slave to a PXL-250 master

route all controllers in a network in spur, hub, or loop configurations

connect earth ground

1

 to the network cable shield - the EntraGuard Titanium automatically connects earth ground to 

the shield at one point on the network to prevent ground loops

use gender changer plugs when making RS-232 serial communication connections (unless you know it is a "straight-
through" plug) - gender changers may have internal wiring changes that can disrupt communications

1. Ground wire is green, with or without yellow tracer.

Summary of Contents for EntraGuard Titanium

Page 1: ...the EntraGuard Titanium Postal Lock Installation Application Note P N 01964 001 NOTE It is the responsibility of the installation organization to have only technically qualified personnel performing...

Page 2: ...ntroller Quick Start Guide Page 2 of 26 P N 01962 001 Rev D Figure 2 The Titanium Telephone Entry Controller NOTE You must power down the unit before attempting to make or remove any connections Failu...

Page 3: ...e or similar device is to be driven by the same power supply as the EntraGuard Titanium controller please ensure the power supply provides enough current to drive every device connected to that supply...

Page 4: ...k length Telephone 1 pair copper phone line NOTE EntraGuard Titanium is not to be used with a Centrex PBX or digital phone line Only use a Plain Old Telephone Service POTS analog phone line Input Powe...

Page 5: ...attached to a controller output use an isolation relay P N IRP 1 if attaching to a parking gate a turnstile or any application using a large electric motor verify the controller s supply voltage is 1...

Page 6: ...g Instructions Refer to Figure 2 on page 2 for all wiring connections 4 1 Terminal Blocks Figure 3 Connecting Wires and Removing Terminal Blocks NOTE Screws on terminal blocks must be tightened secure...

Page 7: ...e of these terminal blocks has a jumper across pins 1 and 2 This terminal block is designated for use on TB 4 If a door switch is not used on the controller this jumper prevents a continuous door open...

Page 8: ...wo possible uses for the general purpose input the master controller may be configured for either Global Unlock see Figure 7 or Auxiliary A door RTE see Figure 8 the slave unit can only be configured...

Page 9: ...Controller Quick Start Guide Page 9 of 26 P N 01962 001 Rev D 4 6 Connecting an Alarm Output Relay Figure 9 Alarm Output Relay Connections 4 7 Connecting a Fail Safe Lock Output Relay Figure 10 Fail...

Page 10: ...EntraGuard Titanium Telephone Entry Controller Quick Start Guide Page 10 of 26 P N 01962 001 Rev D 4 8 Connecting a Fail Secure Lock Output Relay Figure 11 Fail Secure Lock Output Relay Connections...

Page 11: ...r communication between the EntraGuard Titanium unit and the tenants 5 1 1 Single Phone Line for a Single EntraGuard Titanium Unit For a single EntraGuard Titanium unit connect the phone line to TB 15...

Page 12: ...EntraGuard Titanium Telephone Entry Controller Quick Start Guide Page 12 of 26 P N 01962 001 Rev D Figure 13 Single Phone Line for a Multiple EntraGuard Titanium Unit Network...

Page 13: ...enants and one for programming you will not be able to use the internal modem for programming and must use an external modem connected to the RS 232 as described in Section 5 2 2 2 on page 16 Once the...

Page 14: ...der changer plugs or 25 pin to 9 pin adapters when making RS 232 serial port connections These devices may have internal wiring changes that can disrupt communications when implemented in conjunction...

Page 15: ...t use a Keri Systems KDP 252 cable or create a cable according to the drawing in Figure 15 If the host computer has a male DB 25 connector on the serial port you must use a Keri Systems KDP 251 cable...

Page 16: ...s shown in Figure 17 If the modem has a female DB 9 connector you must create a cable as shown in Figure 18 If the modem was purchased from Keri Systems it comes with an adapter that accommodates a fe...

Page 17: ...D 5 2 2 3 Modem Cable Connection An adapter cable is provided when needed with a modem purchased from Keri Systems Connect the adapter cable between the modem and the KDP 336 cable as shown in side A...

Page 18: ...Figure 21 If the modem has a male DB 9 connector and the host computer s serial port has a female DB 9 connector purchase or create a cable as shown in Figure 22 on page 19 If the modem has a male DB...

Page 19: ...anium Telephone Entry Controller Quick Start Guide Page 19 of 26 P N 01962 001 Rev D Figure 22 Modem DB 9M to PC DB 9F PC Serial COM Port Connection Figure 23 Modem DB 9M to PC DB 25F PC Serial COM Po...

Page 20: ...Start Guide Page 20 of 26 P N 01962 001 Rev D 5 3 Network Communication 5 3 1 RS 485 Access Control Network Connection The following figure shows how to connect more than one controller to the access...

Page 21: ...sistance in the cable itself causes a drop in voltage at the end of the run The power supply must be able to account for this voltage drop 7 0 Setup Controller If you re turning system power on for th...

Page 22: ...o this unit you will need to clear the memory separately see Clear the Controller s RAM on page 24 NOTE Changing the address of an EntraGuard Titanium controller completely erases all information with...

Page 23: ...ntrollers on the access control network can identify the master controller For the Master Controller to correctly identify all slave controllers on the network one of two things must be done 1 The mas...

Page 24: ...ization Warning and EntraGuard Default screens see Figure 28 on page 23 and Figure 29 on page 23 until a Total Update from Doors has been performed on the unit or 2 Press 2 to return to the Reset Menu...

Page 25: ...o exit through a secure door they press the RTE button closing the circuit and generating a state change The controller then responds to this state change and generates an output such as unlocking the...

Page 26: ...305 Bering Drive San Jose CA 95131 Unit 17 Park Farm Industrial Estate Ermine Street Buntingford Herts SG9 9AZ UK Telephone 800 260 5265 408 435 8400 Telephone 44 0 1763 273 243 Fax 408 577 1792 Fax 4...

Reviews: