![KERAFLO AYLESBURY KB Installation Manual Download Page 7](http://html1.mh-extra.com/html/keraflo/aylesbury-kb/aylesbury-kb_installation-manual_1956557007.webp)
notes:
Longer chain available on request.
Opposite hand valves available as cost option (chain on left).
SCHD2, SECT 7, G16.5 Water Regs. Gaps should be more if water is turbulent – especially if near valve discharge. 40mm
minimum for valves 1½“ (DN 40mm) or larger – recommended by
keraFlo
.
Typically twice inlet bore. SECT 7, SCHD 2G16.10 Water Regs. Warning/overflow pipes should be capable of taking any possible
flow in the pipe arising from inlet valve failure. See page 8 for side view.
tel 0118 921 9920
fax 0118 921 9921
www.keraflo.co.uk
Warning
tHe float arM Must Be fItteD aBsolutelY
vertIcallY (In tHe oPen PosItIon) as InDIcateD
BY tHe sPIrIt level. (see Below)
MIsalIGnMent wIll Prevent tHe valve froM
closInG. ensure overflow level (B) Is not
lower tHan 200MM froM tHe centre lIne of
tHe valve.
tHe warnInG PIPe anD overflow outlet sHoulD
alwaYs Be aBove tHe HIGHest water level
acHIeveD Before tHe valve closes.
¾”(20)
1”(25)
1¼”(32)
1½”(40)sF
1½”(40)HF
2”(50)sF
sizes (dn):
aylesbury kb valve
p7
dn
20
25
32
40sF
40HF
50sF
size
¾”
1”
1¼”
1½”sF
1½”HF
2”sF
jMin
175
175
175
175
210
210
jMax
1800
1800
1800
1800
1670
1670
k
168
168
168
168
210
210
lMax
200
200
200
200
237
237
M
26o
26o
26o
26o
34o
34o
nMin
160
160
160
160
180
180
nMax
180
180
180
180
220
220
o
70
70
70
70
115
115
PMin
200
200
200
200
330
330
PMax
1825
1825
1825
1825
1815
1815
q
65
65
65
65
120
120
rMin
375
375
375
375
540
540
rMax
2000
2000
2000
2000
2000
2000
sMax
215
215
215
215
268
268
t
26°
26°
26°
26°
34°
34°
WMin
170
170
170
170
320
320
xMax
245
245
245
245
305
305
yMin
500
500
500
500
800
800
a
B
c
D
oPening level (lWl)
xMax
closing level (tWl)
P delayed
action
y Min
(tyPically
requires
additional
500MM
dePtH)
overFloW
B
c
D
sMax
q
oPen
Position
oPening
buoy
e
MiniMuM
oPening level
FroM bottoM
oF tHe tank
WMin
closing
Float
ø50
oPening
buoy
closing
Float
25MM
Min
Warning PiPe
o
lMax
B
closed
Position
k
n
j
a
M
sPirit level
WitH cHain
disconnected
bubble Must
be betWeen
black lines
r
a
t
P delayed
action