background image

Ningbo  Kepo  Electronics Co.,Ltd.

http://www.chinaacoustic.com  

2.1  Out-Diameter   :    

Ø

9mm   

    

外径:

          

Ø

9mm

2.2  Height              :     5.5mm    
    

高度:

          5.5 mm

2.3  Weight             :     1 g.    
      

重量:

          1

2.4 Case Material/Color   :       PBT/Black
       

壳体材质

/

颜色

:     PBT/

2.5 According to the No.7 of RoHS Exemptions,lead-based solder alloys   
      containing 85% by weight or more lead(Sn10Pb90)
      

根据

"

欧盟

RoHS

指令豁免条款

"

7

条规定

,

使用了铅含量超过

85%

的锡铅合金焊料

(Sn10Pb90)

2. 

概要

 

General

 

    This product specification is applied to the  magnetic  transducer  in alarm systems.Please 

contact us when using this product for any other applications than described in the above.

   

本规格书适用于电磁式声响器,通常它用在系统中做报警或提

的 声响器用,

如果将该产品

用于

领域

请与我们取得联

1. 

范围

 

Scope 

Model No. :

Page

Revision No.

Drawing No.

3/9

Specification for Magnetic Transducer

OEM2733

1.0

DAP9050-F5

3. 

额定极限条件

      Maximum Rating

储存温度

范围

Storage Temperature Range

工作温度

范围

Operating Temperature Range

3.3

3.2

3.1

      Item

 

      Specification

-30 

 +80

-20 

 +70

额定电

Rated Voltage 

5V

3.4

工作

Operating  Voltage

4

7V

4.   

电性能

      Electrical Characteristics

4.3

4.1

4.2

      Item

Min.Sound Pressure Level

最小

Resonant Frequency

 

谐掁频率

Max.Rated Current

 

额定电

 

      Specification

85dB/5V/3.2KHz/10cm

3200Hz

70mA/5V

4.4

4.5

Coil Resistance 

 

直流阻抗

Coil Impedance

 

交流阻抗

40

±

4

Ω

80

Ω

Summary of Contents for DAP9050-F5

Page 1: ...RTZ 1 Applied To Product Name Magnetic Transducer Model Name DAP9050 F5 Drawing No OEM2733 Compliance with ROHS SPECIFICATION Signature of KEPO Approved by Signature of Approval Date Issued by Ningbo...

Page 2: ...Scope 2 General 3 Maximum Rating 4 Electrical Characteristics 5 Measurement Block Diagram Response Curve 6 Physical Characteristics 7 Environmental Characteristics 8 Dimensions 9 Packaging Standard 10...

Page 3: ...m systems Please contact us when using this product for any other applications than described in the above 1 Scope Model No Page Revision No Drawing No 3 9 Specification for Magnetic Transducer OEM273...

Page 4: ...ondition Temperature 5 to 35 Humidity 45 to 85 R H unless the standard condition Temperature 25 3 Humidity 60 10 R H is regulated measure 25 3 60 10 R H 5 35 45 85 R H 5 3 Measuring Condition 5 2 Resp...

Page 5: ...ed in natural condition for 4 hours 1 5mm 300 5 3 0 5 260 5 10 1 4 Terminal Strength Pulling 6 5 Solderability 6 4 Soldering Heat Resistance 6 3 No visible damage and cutting off 90 min lead terminals...

Page 6: ...or 30 minutes sounder shall be placed at room temperature 20 After 15 minutes at this temperature sounder shall be placed in a chamber at 80 2 After 30 minutes at this temperature sounder shall be ret...

Page 7: ...AP9050 F5 Ningbo Kepo Electronics Co Ltd http www chinaacoustic com 8 Dimensions UNIT mm Tolerance 0 5 FIRST ANGLE PROJECTION Model No Page Revision No Drawing No 7 9 Specification for Magnetic Transd...

Page 8: ...ty requirements comparable to the applications listed in the above 11 Cautions for Use 11 1 11 2 The component may be damaged if mechanical stress over this specification is applied Please pay attenti...

Page 9: ...ctronics Co Ltd http www chinaacoustic com 12 Revision Specification for Magnetic Transducer Model No Page Revision No Drawing No 9 9 Rev No DATE PAGE DESCRIPTION SIGN OEM2733 1 0 DAP9050 F5 9 2007 11...

Reviews: