021822
228-1949
3
KEPCO, INC.
131-38 SANFORD AVENUE
FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000
FAX (718) 767-1102
www.kepcopower.com
email: [email protected]
4. INSTALLATION INSTRUCTIONS, RA 81-2
4.1 MATERIAL REQUIRED
(See Table 1.)
4.2 INSTALLATION PROCEDURE
Refer to Figure 2 and proceed as follows:
1.
Place the two units side by side as they would be installed in the rack. On the outer side of each unit (not fac-
ing the other unit), mount one L-type bracket with knob (supplied with unit) to each unit using two screws sup-
plied with unit (see Figure 2).
2.
Separate the two units. Install two shoulder screws, flat washers and lockwashers (supplied with Kit) at two
locations on one unit (two threaded holes, A, Figure 3).
3.
Move the two units together and insert the shoulder screws into the corresponding keyhole-shaped openings
in the other unit (see A, Figure 3). Then slide the unit with the shoulder screws forward until the front panels of
both units are flush.
4.
Connect the two units at the rear using linking bracket (see Figure 4) and two screws supplied with Kit. The
two units can now be handled as an assembly and can be installed directly into a 19-inch rack.
FIGURE 2. RA 81-2, INSTALLATION
TABLE 2. MATERIAL REQUIRED, RA 81-1
MATERIAL
Location
QUANTITY
L bracket with knob
Supplied with unit
2
Screws to mount L bracket
Supplied with unit
4
Linking Bracket
Supplied with RA 81-2
1
Screws to attach lining bracket to KLN units
Supplied with RA 81-2
2
Shoulder Screws to secure KLN units to each other
Supplied with RA 81-2
2
Lock washer to secure KLN units to each other
Supplied with RA 81-2
2
Washer to secure KLN units to each other
Supplied with RA 81-2
2