Assembly Instructions

LabMaster 10Zi Rack Mount

Thank you for purchasing a Teledyne LeCroy LabMaster 10Zi Rack Mount accessory. The following procedures explain proper
installation of the rack mount.

Upon receiving your shipment, remove all parts from the packaging. Refer to the Parts Table to ensure that all items have shipped
correctly, and contact us immediately if any parts are missing.

CAUTION.

The LabMaster 10Zi system performance depends on adequate airflow into the vents on the bottom cover of

the units. When installing in a rack, do not position the units so as to block the vents. Any equipment or debris in the 1
inch (25.4 mm) space below the units could result in performance degradation and possible shutdown of the system.

Use the provided tools to complete the assembly.

T10 Torx Driver

2.5mm T-handled,

9" long Allen Key

T25 T-handled Torx Driver

MCMZi

 

Control

 

Module

Pre-Assemble

 

Brackets

Pre-assemble

 

the

 

brackets

 

and

 

handles

 

into

 

a

 

single

 

piece

 

using

 

two

 

8-32

 

Undercut

 

Flat

 

Head

 

screws

 

per

 

bracket,

 

as

 

shown

 

below.

Right Bracket with 3/8 Offset Handle

Left Bracket with 3/8 Offset Handle

9

33203

-00

 

Rev

 

A

1

Environmental Compliance

Unless otherwise specified, all materials and processes are compliant with RoHS Directive 2011/65/EU in its entirety, 

inclusive of any further amendments or modifications of said Directive.

Summary of Contents for LabMaster 10Zi

Page 1: ...so as to block the vents Any equipment or debris in the 1 inch 25 4 mm space below the units could result in performance degradation and possible shutdown of the system Use the provided tools to complete the assembly T10 Torx Driver 2 5mm T handled 9 long Allen Key T25 T handled Torx Driver MCMZi Control Module Pre Assemble Brackets Pre assemble the brackets and handles into a single piece using t...

Page 2: ... the unit using the T10 Torx driver and take off the top cover 2 Remove the three long M3 X 10 and six short M3 X 6 screws on the left side using the T10 Torx driver and take off the cover 3 Remove the two long M3 X 10 and six short M3 X 6 screws on the right side using the T10 Torx driver and take off the cover 4 Remove the five M5 X 12 screws that attach the handle to the left side using the T25...

Page 3: ...sing the 2 5mm T handled 9 Allen key Remove the two M3 X 10 Torx screws from the bottom of the wrap using the T10 Torx driver 6 Stand behind the MCMZi grasp the metal wrap from both sides and pull it off the back of the unit The correct position for removing the wrap is shown below 3 933203 00 Rev A ...

Page 4: ...he right and left bracket are not interchangeable The screw holes should only line up correctly with the handle facing forward 5 With the brackets securely fastened to the unit install the MCMZi into a rack following manufacturer specifications A minimum of two fasteners per side is required There are two additional fastener locations provided in each of the brackets Four fasteners per side is rec...

Page 5: ...tal wrap from both sides and pull it off the front of the unit The bottom trim piece should come off with the wrap 4 Remove the six M3 X 6 Torx screws on the top of the unit using the T10 Torx driver and take off the top cover 5 Remove the three M3 X 10 screws four M3 X 6 screws and one M3 X 4 screw on the right side using the T10 Torx driver and take off the cover 6 Remove the three M3 X 10 screw...

Page 6: ...s should be mounted directly above or below the MCMZi in the rack so that the cables can reach their intended connectors 2 Slide the Acquisition Module into the rack mount tray until it touches the two positioning feet at the back of the tray Do not try to push the unit over the feet CAUTION Due to the weight of the LM10Zi Acquisition Module transporting the unit while mounted in a rack is not rec...

Page 7: ... 5mm Hex T Wrench 9in 42A0000001038 1 Rack Mount Bracket Left 923700 00 1 Rack Mount Bracket Right 923699 00 1 Screw M3x0 5 10mm Clear T 10 916084 00 6 LM10Zi Acqusition Module Description Teledyne LeCroy P N QTY Rack Mount Tray 923513 00 1 2021 Teledyne LeCroy Inc All rights reserved LabMaster and Teledyne LeCroy are trademarks of Teledyne LeCroy Inc Other product or brand names are trademarks or...

Page 8: ......