IMPORTANT NOTES:

1)

This manual is valid for the following Model and associated serial numbers:

MODEL

SERIAL NO.

REV. NO.

2)

A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your
particular model and serial number.

 
3)

The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc. 

 
 

Data subject to change without notice.

KEPCO

®

  

THE POWER SUPPLIER™

MODEL

 

INSTRUCTION MANUAL

ORDER NO.

REV. NO.

KEPCO, INC.  

!

  131-38 SANFORD AVENUE  

!

  FLUSHING, NY. 11355 U.S.A.  

!

  TEL (718) 461-7000  

!

  FAX (718) 767-1102

email: [email protected]  

!

  World Wide Web: http://www.kepcopower.com

KEPCO INC.

An ISO 9001 Company.

RA 60 SERIES

RACK ADAPTER

RA 60, RA 62, AND RA 63

 

 

RA 60 SERIES

RACK ADAPTER

        

     

©2013, KEPCO, INC
P/N 243-0909R4a

Summary of Contents for RA 60

Page 1: ...ntation Office in New York 718 461 7000 requesting the correct revision for your particular model and serial number 3 The contents of this manual are protected by copyright Reproduction of any part ca...

Page 2: ...11355 USA Importer s Name and Address Type of Equipment Rack Adapter Model No PRODUCT MODEL NUMBER Year of Manufacture I the undersigned declare that the product specified above when used in conjuncti...

Page 3: ...igned to operate from single phase three wire TN power systems This equip ment must be installed within a suitably wired equipment rack utilizing a three wire grounded mains connection See wiring sect...

Page 4: ...t ing nameplate located adjacent to the source power connection on the product s rear panel The PROTECTIVE EARTHING CONDUCTOR TERMINAL must be properly con nected prior to application of source power...

Page 5: ...2 5 Installation 2 2 2 5 1 Mounting Ear Installation 2 5 2 6 Wiring Instructions 2 5 2 6 1 Safety Grounding 2 5 2 6 2 Source Power Connections 2 5 2 6 3 Source Power Configurations 2 6 2 6 3 1 A C So...

Page 6: ...Series RA 60 Rack Adapter 1 2 2 1 Key Pin Location 2 1 2 2 Rear Panel Connections 2 2 2 3 Mounting Dimensions 2 3 2 4 Set back Dimensions 2 4 2 5 Mounting Ear Installation 2 5 2 6 Single Phase A C D C...

Page 7: ...RA 60 SERIES 073113 iii LIST OF TABLES TABLE TITLE PAGE 1 1 Rack Adapter Options 1 4 1 2 Accessories 1 4 2 1 Equipment Supplied 2 1...

Page 8: ...iv RA60 SERIES073113 FIGURE 1 1 SERIES RA 60 RACK ADAPTER...

Page 9: ...for all three positions are internally connected for parallel redundant applications RA 62 Output power connections for positions 1 and 2 are internally paralleled position 3 is independent from the o...

Page 10: ...1 2 RA60 SERIES073113 FIGURE 1 2 MECHANICAL OUTLINE DRAWING SERIES RA 60 RACK ADAPTER SHEET 1 OF 2...

Page 11: ...RA60 SERIES073113 1 3 FIGURE 1 2 MECHANICAL OUTLINE DRAWING SERIES RA 60 RACK ADAPTER SHEET 2 OF 2...

Page 12: ...inch rack applications 128 2416 Used for standard flush mounting of RA 60 RA 62 or RA 63 in 23 inch rack see Figure 2 4 128 2415 Used for standard flush mounting of RA 60 RA 62 or RA 63 in 24 inch rac...

Page 13: ...rmediate plate unless the key and keyway align The user can configure each power supply position of the rack adapters for the desired voltage in the desired position the factory default keying is for...

Page 14: ...be taken that the ambient temper ature which is the temperature of the air immediately surrounding the rack adapter does not rise above the specified limits for the operating load conditions of the i...

Page 15: ...pplications the rack adapter is attached to the rack via the two mounting ears two screws are required per mounting ear for proper support b The rack adapter can be attached to the rack using chassis...

Page 16: ...ensure that the temperature immediately surrounding the unit and especially near the air inlets does not exceed the maximum specified ambient temperature for the operating conditions of the installed...

Page 17: ...are described in detail in the following paragraphs and in the operating instructions for HSP Series power supplies 2 6 1 SAFETY GROUNDING Local national and international safety rules dictate the gr...

Page 18: ...inal pairs L1 N1 L2 N2 L3 N3 are connected to the high side and low side contacts of the source power connectors for each of the three power supply mounting positions 1 2 and 3 of the rack adapter see...

Page 19: ...drawn from each phase to minimize the current flow in the source power neutral wire whenever possible When possible the user should wire the rack adapter in accor dance with the instructions for delt...

Page 20: ...O Connector to the terminal of the load and S pin 19 of the I O Connector to the terminal of the load Refer to HSP Operator manual for instructions on wiring NOTE REGARDLESS OF OUTPUT CONFIGURATION O...

Page 21: ...arding parallel redundant load operation 2 6 5 2 SERIES INDEPENDENT OPERATION RA 63 rack adapters can be used for either independent or series operation of HSP power sup plies For series operation ins...

Page 22: ......